background image

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-6247  P. 1 / 7

INSTRUCTION MANUAL

MODBUS I/O MODULE

(4 points, RMS sensing, clamp-on current sensor input)

MODEL

R10M-CT4E

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Modbus I/O module .............................................................(1)
Terminal resistor (110Ω, 0.25W) ........................................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.
For information on Modbus specification, refer to the Mod-
bus Protocol Reference Guide (EM-5650).
This manuals is downloadable at M-System’s web site 
(https://www.m-system.co.jp).

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVES

• The equipment must be mounted inside the instrument 

panel of a metal enclosure.

• The actual installation environments such as panel con-

figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated 
in a panel system.  The user may have to review the CE 
requirements in regard to the whole system and employ 
additional protective measures to ensure the CE conform-
ity.

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product 

and confirm its operational range as indicated below: 
24V DC rating: 24V ±10%, approx. 90mA

 

GENERAL PRECAUTIONS

• Before you remove the terminal block or mount it, turn off 

input signals for safety.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C 

(14 to 131°F) with relative humidity within 10 to 90% RH 
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

Summary of Contents for R10M-CT4E

Page 1: ...s connected devices connected wires may af fect the protection level of this unit when it is integrated in a panel system The user may have to review the CE requirements in regard to the whole system...

Page 2: ...during no Modbus communication Error ON Red Abnormality occurs in the unit i g memory failure OFF Normal status SD ON Green Sending data via RS 485 RD ON Green Receiving data via RS 485 TERMINAL ASSIG...

Page 3: ...t CLSE 40 0 00 400 00 full input CLSE 60 0 00 600 00 full input Full Input CLSE R5 0 000 5 000 zero input 0 000 CLSE 05 0 00 50 00 zero input CLSE 10 0 00 100 00 zero input CLSE 20 0 00 200 00 zero in...

Page 4: ...ARALLEL Mounting the unit A Hook the upper hook at the rear side of the base onto the DIN rail B Push the lower part of the unit in the direction of the arrow until the base is firmly fixed to the DIN...

Page 5: ...NSIONS unit mm inch DIN rail 35mm wide When mounting no extra space is needed between units 36 1 42 7 28 5 20 89 3 50 5 20 7 28 72 2 83 80 3 15 45 1 77 4 16 CONNECTION DIAGRAM 1 6 2 7 3 8 4 9 Jack 12...

Page 6: ...SLD FE TERMINATOR TERMINATOR Note The terminator must be connected across DA and DB at both ends of communication line WIRING COMMUNICATION WITH HOST PC MODBUS I O MODULE WIRING INSTRUCTIONS FOR BASE...

Page 7: ...ge error Input Register 3X 1 I Analog Input analog input 1 2 I Analog Input analog input 2 3 I Analog Input analog input 3 4 I Analog Input analog input 4 Note DO NOT access addresses other than the o...

Reviews: