background image

O P E R A T I N G   I N S T R U C T I O N S

ReLy OSSD4

Safety relay

RLY3-OSSD400S14

Содержание ReLy OSSD4

Страница 1: ...O P E R A T I N G I N S T R U C T I O N S ReLy OSSD4 Safety relay RLY3 OSSD400S14...

Страница 2: ...ssible within the limits of the legal determination of Copyright Law Any modi fication abridgment or translation of this document is prohibited without the express written permission of SICK AG The tr...

Страница 3: ...e overview 10 4 2 2 Interfaces 10 4 2 3 Compatible sensor types 10 4 2 4 External device monitoring 11 4 2 5 Status indicators 11 5 Project planning 12 5 1 Manufacturer of the machine 12 5 2 Operating...

Страница 4: ...ing 22 10 1 Disposal 22 11 Technical data 23 11 1 Data sheet 23 11 2 Dimensional drawings 26 11 3 Internal circuitry 27 12 Annex 28 12 1 Compliance with EU directives 28 13 List of figures 29 14 List...

Страница 5: ...le 1 Ordering information Part Usage Type Part number ReLy OSSD4 Opto electronic protec tive devices RLY3 OSSD400S14 1112276 ORDERING INFORMATION 1 8026008 2020 07 28 SICK O P E R A T I N G I N S T R...

Страница 6: ...e manufacturer and the entity operating the machine in which the device is to be integrated Area of responsibility Target group Specific chapters of these operating instruc tions 1 Manufacturer Projec...

Страница 7: ...er which may lead to moderate or minor injuries if not prevented NOTICE Indicates a situation presenting possible danger which may lead to property damage if not prevented NOTE Indicates useful tips a...

Страница 8: ...ed and or used conductor bound RF energy that is required for the inner function of the device itself occurs The safety relay must only be used within the limits of the prescribed and specified techni...

Страница 9: ...ask a person is considered qualified when he she has the expertise and experience in the relevant field and is sufficiently familiar with the application of the protective device on the machine to be...

Страница 10: ...61 62 Figure 1 Device overview 1 Device unlocking 2 LEDs 3 Front connector unlocking 4 Front connector 4 2 2 Interfaces Inputs 2 safety capable inputs Outputs 4 enabling current paths safe Feedback c...

Страница 11: ...LEDs The labeled positions are only partially assigned LEDs The positions and their labeling except for the upper 2 lines also show the pin assignment of the terminals on the front connector Table 2...

Страница 12: ...risk assessment may require the entity operating the machine to meet the obligations of a manu facturer b Apart from the procedures described in this document the components of the safety relay must...

Страница 13: ...tective device b Ensure the enabling current paths are supplied by the same voltage supply 5 4 2 Feedback current path The feedback current path is used as external device monitoring for the monitorin...

Страница 14: ...efects as a result of modifications or other influences e g damage or manipulation The manufacturer and user must define the type and frequency of the thorough checks on the machine on the basis of th...

Страница 15: ...is done in accordance with EN 50274 and electrical installation in accordance with IEC 60204 1 in the control cabinet with enclosure rating IP54 Mounting must be done on a non flammable base Mounting...

Страница 16: ...om the mounting rail 6 4 Module exchange Approach 1 Disconnect module and the connected components from all voltage sources 2 Take front connector with connected cables off the defective device Press...

Страница 17: ...the new module First mount in the module with bent hook and then engage in the housing Click Figure 8 Mount the front connector The front connector engages with an audible click MOUNTING 6 8026008 202...

Страница 18: ...s 2 UL 1310 The external voltage supply must be capable of bridging a brief power failure of 20 ms as specified in IEC 60204 1 Suitable power supply units are available as accessories from SICK The sa...

Страница 19: ...1 I2 CH2 input safety capable input for OSSD 2 3 A2 Voltage supply 0 V DC 1 The enabling current paths must be supplied by the same voltage supply 2 The enabling current path and external device monit...

Страница 20: ...mounting or the electrical installation After exceptional events such as after manipulation has been detected after modification of the machine or after replacing components The thorough check ensure...

Страница 21: ...ine fault cannot be definitively determined or safely rectified immediately shut the machine down b Secure the machine so that it cannot switch on unintentionally NOTE Additional information on troubl...

Страница 22: ...in accordance with national waste disposal regulations Complementary information SICK will be glad to help you dispose of these devices on request 10 DECOMMISSIONING 22 O P E R A T I N G I N S T R U C...

Страница 23: ...internal fault detection and is unable to assume a safe status in the event of a fault Fault detection is performed by the connected safety related logic unit Stop category 0 IEC 60204 1 1 The requir...

Страница 24: ...al Silver alloy gold flash plated Switching voltage for enabling current paths At altitudes below 2 000 m above sea level 10 V DC 230 V DC 30 V DC 10 V AC 230 V AC At altitudes 2 000 m above sea level...

Страница 25: ...nding air temperature 25 C 55 C At altitudes 2 000 m above sea level 3 000 m above sea level 25 C to 50 C At altitudes 3 000 m above sea level 4 000 m above sea level 25 C 45 C Storage temperature 25...

Страница 26: ...itching operations 1 000 2 Switching current A 11 2 Dimensional drawings 30 1 28 85 5 87 7 124 6 64 4 128 3 78 7 120 7 Figure 12 Dimensional drawing 11 TECHNICAL DATA 26 O P E R A T I N G I N S T R U...

Страница 27: ...11 3 Internal circuitry Figure 13 Internal circuitry TECHNICAL DATA 11 8026008 2020 07 28 SICK O P E R A T I N G I N S T R U C T I O N S ReLy OSSD4 27 Subject to change without notice...

Страница 28: ...l specifications stated in the EU declaration of conformity have been used as a basis for this Complete EU declaration of conformity for download You can call up the EU declaration of conformity and t...

Страница 29: ...ector 16 8 Mount the front connector 17 9 Terminals on front connector 19 10 Switch off delay without continuous arcing 25 11 Electrical endurance of contacts 13 14 23 24 33 34 and 43 44 26 12 Dimensi...

Страница 30: ...1 6 Safety related parameters 23 7 Mechanical data 23 8 Electrical data safety capable inputs I1 I2 24 9 Electrical data enabling current paths 13 14 23 24 33 34 43 44 signaling current path 51 52 and...

Страница 31: ...LIST OF TABLES 14 8026008 2020 07 28 SICK O P E R A T I N G I N S T R U C T I O N S ReLy OSSD4 31 Subject to change without notice...

Страница 32: ...8080 7425 E Mail enquiry my sick com Mexico Phone 52 472 748 9451 E Mail mexico sick com Netherlands Phone 31 0 30 229 25 44 E Mail info sick nl New Zealand Phone 64 9 415 0459 0800 222 278 tollfree...