Decrease the suggested field
If you walk the imaginary field on its borders and, e.g. hold a board or cardboard into
the laser beam, the surrounding contour is thereby limited. As long as the
Propose field
function is active, the proposed field is reduced to the respectively measured surround‐
ing contour.
Approach
1.
Select field type.
2.
Click on
Propose field
.
✓
The safety laser scanner scans the contour of the room.
3.
If necessary, reduce the size of the suggested field.
4.
Click on
Propose field
again.
✓
The Safety Designer displays the proposed field.
7.9
Inputs and outputs, local
Overview
Figure 55: Inputs and outputs, local
1
Overview: plug connector of the safety laser scanner
2
Pin assignment
3
Available signals
4
Remove signal from connection
5
Further settings for some signals
CONFIGURATION
7
8023152/160F/2019-11-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
89