Operating Instructions
NAV350
Mounting
8013889/ZML0/2017-06-09
© SICK AG · Germany · All rights reserved · Subject to change without notice
43
Chapter
4
4
Mounting
Important
Do not open the housing for the NAV350. If the housing is opened, any warranty claims
against SICK AG will be rendered void.
4.1
Overview of the mounting steps
•
select mounting method for the NAV350
•
mounting and adjusting the NAV350
4.2
Preparations for mounting
4.2.1
Components to be mounted
•
NAV350 (weight approx. 2.4 kg (5.29 lb)
4.2.2
Material and accessories necessary
•
Fixing bracket by the user:
– Stable mounting bracket that provides adjustable alignment of the NAV350 in the X
and Y axis
– 3 screws M6 for the NAV350, screw length dependent on the wall thickness of the fix-
ing bracket used
4.3
Mounting and adjustment of the device
Risk of damage to the device!
The maximum screw length in the M6 blind threaded hole is 12 mm (0.47 in). Longer
screws will damage the NAV350.
Use screws of suitable length.
The NAV350 has three M6 blind thread holes and is fastened using 3 M6 screws (see
section 9.2.1 “Dimensional drawing NAV350” on page 65
).
For secure mounting at least 3 M6 screws with washers and locking washers are required.
The supply of power must be switched off.
The NAV350 can be fitted in any position.
1. Prepare surface from mounting the fixing bracket for the NAV350 as described in
section 4.2 “Preparations for mounting” on page 43
.
2. Insert screws in the holes in the bracket and screw into the blind threaded hole in the
NAV350. Only tighten screws lightly.
3. The scanner head on the NAV350 must be free to rotate.
4. Align the NAV350.
5. Tighten screws.