131
GB
MSL coded version
8 007 898/O369/05-04-04 Operating instruction • MSL cod. © SICK AG • Industrial Safety Systems • Germany • All rights reserved
Operating range 15 to 70 m
Operating range 0,5 to 18 m
The link between pins 5 and 6 must be made at the connection terminal block
for PG and Hirschmann connection versions. For Interconnectron and Harting
versions the link must be made in the socket.
*)
*)
*) reserved, do not use
1
3
4
5
6
2
7
+24 VDC
Test
➞
Test
n. c. *)
n. c. *)
0 V
PE
➞
1
3
4
5
6
2
7
+24 VDC
Test
➞
Test
0 V
PE
➞
Change of material
To ensure optimum ESD protection the
material used for the terminal chamber –
equipped with Interconnectron or
Harting plugs – has been changed from
plastic to metal.
3.2.2 Operating range
adjustment
24 V DC
Operating v24 V
0 V
Signal ground (0 V)
Test
Test-contact connection
RW
Operating range adjustment
PE
Protective earth conductor
OSSD1
Safety Output 1
OSSD2
Safety Output 2
RES
Reset input
EDM
External device
monitoring input
OWS
Contamination signal output
If Interconnectron plugs are used
(
Fig. 6, appendix
), use only reliable power
supplies to VDE 551.
The
illustration
shows the two connection
possibilities for the sender range options.
The meaning of the individual connections
is as follows:
241967_MSLcv_GB_3.p65
10.12.04, 09:40
131