8.3.2.5
Two point mode
For each switching point (SP1 and SP2), two point mode defines an upper switching
limit and a lower switching limit within which the switching output is switched to active
or deactivated.
This mode does not use a hysteresis.
NOTE
Two point mode can only be set via IO-Link.
If this mode has been set, it can still be used even without an IO-Link connection.
SP1
SP2
„0“
„1“
WR
Figure 12: Switching behavior in two point mode (default: top; inverted: bottom)
SP1
Switching point SP1
SP2
Switching point SP2
WR
Working range
8.4
Teach-in mode
8.4.1
General information on teach-in mode
In teach-in mode, the current mode is displayed by the LEDs lighting up in a specific
way.
8.4.1.1
Calling up teach-in mode
To activate teach-in mode, press and hold the keypad until the required teach-in mode
is reached.
8.4.1.2
Timeouts
After 90 seconds of inactivity, the sensor automatically exits teach-in mode and reverts
to normal operation.
If the keypad is pressed and held for more than 15 seconds in teach-in mode, this will
also cause the sensor to exit teach-in mode.
A timeout is also triggered if a teach-in process has been started and no activity is
registered at the keypad for 30 seconds after this.
8
OPERATION
22
O P E R A T I N G I N S T R U C T I O N S | MPS-C
8019721.1FIH/2022-06-01 | SICK
Subject to change without notice