8.4.4.3
Teaching in the switching range (window mode)
1.
Push the piston to the first switching point.
2.
Press the keypad.
3.
Hold the keypad between 11 and 15 seconds.
✓
The blue status LED flashes slowly.
2 Hz
4.
Lift your finger.
5.
Hold the keypad between 6 and 9 seconds.
6.
Lift your finger.
✓
The first switching point is defined. The green and yellow LEDs flash slowly.
2 Hz
2 Hz
7.
Push the piston to the second switching point.
8.
Press the keypad.
✓
The second switching point is defined.
1 s
1 s
NOTE
The process of teaching in a measuring range may be aborted (yellow LED flashes 4
times):
•
No magnet detected when teaching in the start or end of the measuring range.
•
Value below minimum measuring range (< 1 mm).
8
OPERATION
30
O P E R A T I N G I N S T R U C T I O N S | MPS-C
8019721.1FIH/2022-06-01 | SICK
Subject to change without notice