O PE R A T I N G I N S T R U C T I O N S | MICS3/OS3 electr. protection hood
Subject to change without notice
INSTALLATION
4
4
Installation
4.1
Preparing support unit
A support unit/mounting plate must be prepared to mount the protection hood. Observe
dimensions.
Fig. 6: Dimensional drawing
For mounting position 1 (to the rear, see
Chapter 4.2 Mounting plate, page 16
), an opening
must be provided for the supply connection of the M12 4-pin A-coded male connector.
The male connector requires an opening in the customer object (machine/wall) with a
diameter of at least 45 mm.
CAUTION
Hazard due to hand injuries caused by crushing
▸
During the entire installation phase, the MICS3/OS3 electr. protection hood is
disconnected from the voltage.
Legend
1
Protection hood open
2
Protection hood closed
3
Mounting with 2x M8 screw, washers and self-locking nuts. Recom
-
mended screw strength 10.1, stainless steel
4
Scan plane
5
Base
6
Laser scanner field of view