13
8025999/V1-0/2021-02| SICK
O PE R A T I N G I N S T R U C T I O N S | MICS3/OS3 electr. protection hood
Subject to change without notice
PRODUCT DESCRIPTION
3
3.3
Technical data
3.4
Mounting kit 1a
Features
●
Mounting kit 1a is pre-mounted to the mounting bracket
●
Fastening safety laser scanner under the hood
●
SICK part number 2073851
Fig. 4: Mounting kit 1a
Material
Stainless steel, aluminum
Dimensions when in closed status width x
height x length
217 x 232 x 284 mm
Communication interface - actuator
24 V
Imax 1.9A
Connection - M12 4-pin A-coded male connec
-
tor
Ambient operating temperature
-25 ° ... +50 °C
Actuator protection class
IP66
Actuator stroke
72 mm
Weight:
– Protection hood without scanner
– Protection hood with scanner
6.5 kg
7.9 kg