background image

 

Further locations at 

www.sick.com

Australia

Phone +61 3 9457 0600

 

1800 334 802 – tollfree

E-Mail  [email protected]

Austria

Phone +43 22 36 62 28 8-0

E-Mail  [email protected]

Belgium/Luxembourg

Phone  +32 2 466 55 66

E-Mail  [email protected]

Brazil

Phone +55 11 3215-4900

E-Mail  [email protected]

Canada

Phone +1 905 771 14 44

E-Mail  [email protected]

Czech Republic

Phone +420 2 57 91 18 50

E-Mail  [email protected]

Chile

Phone +56 2 2274 7430

E-Mail  [email protected]

China

Phone +86 20 2882 3600

E-Mail  [email protected]

Denmark

Phone +45 45 82 64 00

E-Mail  [email protected]

Finland

Phone +358-9-2515 800

E-Mail  [email protected]

France

Phone +33 1 64 62 35 00

E-Mail  [email protected]

Germany

Phone +49 211 5301-301

E-Mail  [email protected]

Hong Kong

Phone +852 2153 6300

E-Mail  [email protected]

Hungary

Phone +36 1 371 2680

E-Mail  [email protected]

India

Phone +91 22 6119 8900

E-Mail [email protected]

Israel

Phone +972 4 6881000

E-Mail  [email protected]

Italy

Phone +39 02 274341

E-Mail  [email protected]

Japan

Phone +81 3 5309 2112

E-Mail  [email protected]

Malaysia

Phone +6 03 8080 7425

E-Mail  [email protected]

Mexico

Phone +52 (472) 748 9451

E-Mail [email protected]

Netherlands

Phone +31 30 2044 000

E-Mail  [email protected]

New Zealand 

Phone +64 9 415 0459

 

0800 222 278 – tollfree

E-Mail  [email protected]

Norway 

Phone +47 67 81 50 00

E-Mail  [email protected]

Poland

Phone +48 22 539 41 00

E-Mail  [email protected]

Romania

Phone +40 356 171 120 

E-Mail  [email protected]

Russia

Phone +7 495 775 05 30

E-Mail  [email protected]

Singapore

Phone +65 6744 3732

E-Mail  [email protected]

Slovakia

Phone +421 482 901201

E-Mail  [email protected]

Slovenia

Phone +386 591 788 49

E-Mail  [email protected]

South Africa

Phone +27 11 472 3733

E-Mail [email protected]

South Korea

Phone +82 2 786 6321

E-Mail  [email protected]

Spain

Phone +34 93 480 31 00

E-Mail  [email protected]

Sweden

Phone +46 10 110 10 00

E-Mail  [email protected]

Switzerland

Phone +41 41 619 29 39

E-Mail  [email protected]

Taiwan

Phone +886 2 2375-6288

E-Mail  [email protected]

Thailand

Phone +66 2645 0009

E-Mail  [email protected]

Turkey

Phone +90 216 528 50 00

E-Mail  [email protected]

United Arab Emirates

Phone +971 4 88 65 878

E-Mail  [email protected]

United Kingdom

Phone +44 1727 831121

E-Mail  [email protected]

USA

Phone +1 800 325 7425 

E-Mail  [email protected]

Vietnam

Phone +84 945452999

E-Mail  [email protected]

SICK AG

  

|

  

Waldkirch

  

|

  

Germany

  

|

  

www.sick.com

8021473/2017-08-08/en

Содержание MAX48

Страница 1: ...T E C H N I C A L I N F O R M A T I O N MAX48 Non contact position sensors...

Страница 2: ...ssible within the limits of the legal determination of Copyright Law Any modifica tion abridgment or translation of this document is prohibited without the express writ ten permission of SICK AG The t...

Страница 3: ...12 4 1 5 Bore hole for the connector system 13 4 1 6 Piston for the position magnet 14 4 2 Installing the position magnet 15 4 3 Location of the O ring and support ring 16 4 4 Installing the sensor in...

Страница 4: ...storage conditions 26 8 Maintenance 27 8 1 Checking the device function 27 8 2 Error table 28 8 3 Repairs 28 9 Decommissioning 29 9 1 Dismantling 29 9 2 Disposal 29 10 Technical data 30 10 1 Analog M...

Страница 5: ...ined on the device Only trained electricians are permitted to carry out work on the electrical system or electrical assemblies 1 3 Further information MAX48 Operating Instructions Product web page for...

Страница 6: ...gainst dust climatic influences vibrations surrounding media as well as electrical and magnetic fields The device is an accessory and must be connected to a suitable electronic control unit 2 3 Respon...

Страница 7: ...his Technical Information b Must be made available for reference b Must be conveyed to new owners SAFETY INFORMATION 2 8021473 2017 08 08 SICK T E C H N I C A L I N F O R M A T I O N MAX48 7 Subject t...

Страница 8: ...DC 10 Electrical Interface V Voltage A Current 11 Signal output 10 Analog 4 00 20 00 VDC 21 Analog 4 75 0 25 VDC 40 Analog 1 00 9 00 VDC 12 13 Connection type A 4 pin analog 1 VDC 2 n c 3 GND 4 OUT B...

Страница 9: ...in the measuring device when installed in the pis ton The position magnet is located inside the piston and moves over the pressure pipe without contacting it The magnet field thereby produced identif...

Страница 10: ...vels to the converter 5 and the sensor electronics produce an electrical output signal The time interval between the current pulse and the detection of the structure borne sound wave is measured and e...

Страница 11: ...the housing 3 Diameter for the electrical connection 4 Depth for the electrical connection b Prepare an installation cavity for the sensor in accordance with the following dimensions Table 4 Installa...

Страница 12: ...nd an addition distance of 3 mm 4 1 3 Insertion chamfer To ensure proper and secure installation of the device in the cylinder a insertion cham fer must be provided NOTICE Risk of damage to the device...

Страница 13: ...ue for the retaining screw 0 5 Nm 1 0 Nm based on the max permissible force on the housing surface 4 1 5 Bore hole for the connector system b Prepare an installation cavity for the connector system an...

Страница 14: ...sions of the connector system bore hole 4 1 6 Piston for the position magnet b Prepare an installation cavity for the position magnet in accordance with the fol lowing dimensions 1 5 0 06 1 1 H13 0 04...

Страница 15: ...st not rub against the pressure pipe Observe the operating pressures see Technical data page 30 3 2 1 4 Figure 11 Installation of the position magnet 1 Corrugated spring washer 2 Position magnet 3 Cir...

Страница 16: ...he mating connector ensure that it also has an enclosure rating of IP69K Figure 13 Installation steps 1 Lubricate the O ring and support ring 2 Guide the connector system and its connecting cables car...

Страница 17: ...ce during installation Forces acting on the load bearing features of the housing can damage the device b Do not apply any load on the pressure pipe or behind the head of the device when mounting the s...

Страница 18: ...a suitable tool to produce a gas tight crimp ESD protection protect workplaces and persons from electrostatic discharge Prevent fluid ingress Use suitable caps to seal the male connector after instal...

Страница 19: ...l it contacts the flange plate on the connector as desired Always use a torque of 5 Nm to tighten the cap Make sure no paint particles get onto the thread or pin contacts Any paint particles on the ou...

Страница 20: ...or cylinder pipe Never perform welding work directly on the cylinder Never perform welding work near a cylinder if it has a built in sensor Welding currents and similar effects can also arise at any...

Страница 21: ...tor system 4 3 1 2 Figure 16 M12 pin assignment Pin assignment as per position 13 of the type code Table 8 M12 pin assignment Type code A B M 12 24 VDC 1 1 2 GND 0 V 3 3 3 Signal 4 2 4 n c 2 4 1 Table...

Страница 22: ...e grounding must be provided e g by connecting a ground strap directly to the cylinder Cable shielding The device is adequately shielded by the cylinder when installed and therefore has not been provi...

Страница 23: ...The supply voltage ripple see Technical data page 30 and other sources of interference e g electromagnetic interference can also affect the quality of the analog output signal To reduce the noise whe...

Страница 24: ...ted information Table 12 Tolerances when operating the device without teach in Example for a measuring range of 400 mm Range 4 000 mV 16 mA Signal 0 5 4 5 V 4 20 mA Zero end point 1 0 mm 10 mV 0 04 mA...

Страница 25: ...Typical values VDC mA Cylinder stroke mm 200 400 800 200 400 800 Tolerances 50 mV 25 mV 15 mV 0 20 mA 0 10 mA 0 05 mA COMMISSIONING 6 8021473 2017 08 08 SICK T E C H N I C A L I N F O R M A T I O N M...

Страница 26: ...ther ensure no male connectors or cables are crushed Cover the connectors any free cable ends with an anti static bag The original packag ing for example is suitable for this purpose The dust protecti...

Страница 27: ...Figure 19 Measuring the output signal in VDC 1 Switch the measuring range of the multimeter to VDC 2 Connect the multimeter to the signal lead and 0 V lead 3 Connect the voltage supply 12 24 V 4 Conne...

Страница 28: ...linder bore hole too small Damage to the device components when installing the device Not noticing pointy or sharp edges Damage to male connectors wires cables Careless handling of the device Damage t...

Страница 29: ...hich can no longer be used must be disposed of in an environmentally friendly manner in accordance with the applicable country specific waste disposal regu lations As the device is categorized as elec...

Страница 30: ...up phase max 0 25 mm Interface Electrical interface Analog Voltage signal 0 25 4 75 VDC 0 50 4 50 VDC 0 50 9 50 VDC 1 00 9 00 VDC Current signal 4 20 mA Electrical connection M12 male connector 4 pin...

Страница 31: ...ss fiber reinforced polyamide nickel gold plated brass contacts M12 flange Stainless steel with O ring NBR70 Ambient data EMC EU Directive 2014 30 EU CE marking EU Directive 2009 64 EU Agricultural ma...

Страница 32: ...shocks per spatial axis ISO 16750 3 IEC 60068 2 27 50 g 11 ms Resistance to vibrations 10 mm pressure pipe Sine ISO 16750 3 IEC 60068 2 6 10 55 Hz 3 5 mm pp 55 2 000 Hz 20 g 24 hrs Sine on random ISO...

Страница 33: ...et 1 2 3 Figure 25 Dimensional drawing for position magnet 1 Outer diameter 2 Inner diameter 3 Height Table 18 Dimensions of position magnet Outer diameter 17 4 mm 0 1 Inner diameter 12 0 mm 0 1 Heigh...

Страница 34: ...gress of cleaning agents into the electronics when washing cylin ders with an in built MAX linear encoder Brass cap for ingress protection when washing cylinders with an in built linear encoder Please...

Страница 35: ...ANNEX 11 8021473 2017 08 08 SICK T E C H N I C A L I N F O R M A T I O N MAX48 35 Subject to change without notice...

Страница 36: ...Mexico Phone 52 472 748 9451 E Mail mario garcia sick com Netherlands Phone 31 30 2044 000 E Mail info sick nl New Zealand Phone 64 9 415 0459 0800 222 278 tollfree E Mail sales sick co nz Norway Pho...

Отзывы: