4
Mounting
4.1
Preparation for installing the sensor
4.1.1
Installation cavity for the sensor
The method of installation depends on the cylinder design. Generally, the sensor is
installed from the piston rod side. It is also possible to install the sensor from the head
side of the cylinder.
The sensor dimensions are listed in the technical specifications:
.
Fit dimensions and tolerances
4 2
3
1
Figure 3: Dimensions of the sensor installation cavity
1
Diameter for the housing
2
Depth for the housing
3
Diameter for the electrical connection
4
Depth for the electrical connection
b
Prepare an installation cavity for the sensor in accordance with the following
dimensions.
Table 4: Installation cavity for the housing and electrical connection
Type
Installation cavity for housing
Installation cavity for electrical connec‐
tion
1
Ø
2
Depth
3
Ø min. ... Ø max.
4
Depth
MAX48
48H8
21.2 mm + 0.2
d > 32.5 mm
d < 40 mm
≥ 10 mm
Mean roughness value of the surface: Ra < 0.8 mm.
4.1.2
Installation cavity for the piston rod
1
2
3
4 5
>3
(0.12)
Figure 4: Installation cavity for the piston rod and pressure pipe
1
Null zone
MOUNTING
4
8021473/2017-08-08 | SICK
T E C H N I C A L I N F O R M A T I O N | MAX48
11
Subject to change without notice