Online help
LMS400
Configuration
8011984/YSZ3/2016-02-04
© SICK AG · Germany · All rights reserved · Subject to change without notice
11
Chapter
3
Fig. 2:
Gamma angle
How to define the angles of the LMS400:
3.3.3
Measurement area
You define the working area relevant for the Level Control application as the measurement
area. You define for this measurement area a left and right border as well as a top and
bottom border. All four values refer to the global zero point defined previously.
Fig. 3:
Measurement area
Notes
Ensure that the zero point is on the right and Y extends to the left. For this reason the
value for the left border is always greater than the value for the right border.
The bottom border can also have a negative value, e.g. to include the conveyor system
in the evaluation.
Gamma
Z
LMS400
Y
Open in the P
ROJECT
TREE
, LMS400-XX00, P
ARAMETER
the device page P
OSITION
.
In the A
NGLE
area enter the values for the measurement area borders in the fields.
Top border,
e.g. 500 mm
Bottom border,
usually 0 mm
Right border,
usually 0 mm
Left border,
e.g. 1200 mm
Measurement
area
Zero point