11.1
Features
Type
Lector610
Lector611
Focus
Depends on type,
.
Optical focus methods
•
Adjustable focus with focus adjustment tool
•
Liquid lens, automatic focus adjustment
Sensor resolution
Depends on type,
.
Integrated illumination
unit
8 LEDs:
•
4 LEDs with visible amber light (λ = 617 nm ± 50 nm)
•
4 LEDs with visible blue light (λ = 470 nm ± 15 nm)
Feedback LED (spot in field
of view)
1 LED:
•
Visible green light (λ = 525 nm ± 15 nm)
•
Visible red light (λ = 635 nm ± 15 nm)
LED alignment aid (2
points in the field of view)
2 LEDs, can be deactivated:
Visible red light (λ = 630 nm ± 15 nm)
LED risk group
Integrated illumination unit:
Risk group 1 (low risk) according to IEC 62471-1: 2006-07 / EN
62471-1: 2008-09 including EU Directive 2006/25 / EC (DIN EN
62471:2009-03 is identical to EN 62471:2008-09).
Radiance
•
L
B
1)
: < 10 x 10
3
W/(m
2
sr) within 100 seconds; at distance
≥ 200 mm
•
L
R
2)
: < 2.2 x 10
6
W/(m
2
sr) within 10 seconds; at dis‐
tance ≥ 200 mm
Distance-dependent hazard value
•
Risk group 0 (no risk) based on L
B
1)
: < 100 W/(m
2
sr) within
10,000 seconds; at a distance of > 2.0 m.
Feedback LED, LED alignment aid and status LEDs
:
Risk group 0 (no risk) according to IEC 62471-1: 2006-07 / EN
62471-1: 2008-09 including EU Directive 2006/25 / EC (DIN EN
62471:2009-03 is identical to EN 62471:2008-09).
MTBF of LEDs
Integrated illumination unit, feedback LED and LED alignment
aid:
75,000 h, at 25 °C ambient operating temperature
Time-of-flight sensor
1 laser (distance measurement in configuration mode):
Invisible infrared light (wavelength 940 nm, maximum output
power ≤ 17.5 mW, pulse length ≤ 3.7 ns)
Laser class
Time-of-flight sensor:
Class 1 Laser Product according to EN/IEC 60825-1:2014. Com‐
plies with 21 CFR 1040.10 except for conformance with IEC
60825-1 Ed. 3.0 as described in “Laser Notice 56” dated May
8, 2019.
TECHNICAL DATA
11
8024830/1FGB/2022-03-29 | SICK
O P E R A T I N G I N S T R U C T I O N S | Lector61x
55
Subject to change without notice