![SICK Lector61 Series Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/sick/lector61-series/lector61-series_operating-instructions-manual_1264266041.webp)
Wiring data interfaces via a connection module
Connection modules
Data interface
Reference
CDB650-204
RS-232
see "Wiring serial host inter‐
face RS-232 of the device in
CDB650-204", page 64
CDM420-0006
RS-232
see "Wiring serial host interface
RS-232 of the device in the
CDM420-0006", page 73
6.5.4
Wiring the CAN interface
NOTE
Activate the CAN data interface in the device with a configuration tool, e.g., the configu‐
ration software SOPAS ET.
Make further settings in the device corresponding to the function of the device in the
system configuration.
Wiring CAN interfaces via a connection module
Connection modules
Interface
Reference
CDB650-204
CAN
see "Wiring the CAN interface of
the device in the CDB650-204",
page 65
CDM420-0006
CAN
see "Wiring the CAN interface of
the device in the CDM420-0006",
page 74
6.5.5
Wiring the digital inputs
The device has 2 switching digital inputs (Sensor1, Sensor 2).
Functions (examples)
•
Start and end external reading cycle.
•
Feed in incremental signal.
Position of digital inputs
•
Male connector of the device cable (M12, 17-pin, A-coded)
•
Adapter cable (female connector, M12, 17-pin, A-coded/male connector, D-Sub-
HD, 15-pin)
•
Open end of the adapter cable (female connector, M12, 17-pin, A-coded/open
end)
All digital inputs are available at the individual positions.
Signal
3
52.3 K
3 K
"
§
$
Sensor GND
V
S
2
V
S
V
S
V
in
5
!
PNP sensor
1
GND
GND
Switching input of device
4
GND
V
S
Figure 24: Wiring a digital input
1
Trigger sensor (PNP sensor)
ELECTRICAL INSTALLATION
6
8024830/1FGB/2022-03-29 | SICK
O P E R A T I N G I N S T R U C T I O N S | Lector61x
41
Subject to change without notice