outputs any read results via the data interface.
✓
The device runs through all possible functions without executing them and then
starts again from the beginning. The LEDs light up one after the other for 1.5 sec‐
onds for each function in the third display level (functions:
Test
,
Aiming
,
Focus
,
Tuning
). The device cyclically repeats the process.
2.
To execute a function while the corresponding indication LED is lit, briefly press the
function button (
p
) once.
Example: To switch to the
Focus
mode while the
Focus
indication LED is lit, briefly
press the function button (
p
) once.
Ready
5
0
7
0
1
2
0
2
0
0
3
0
0
Light
Test
Aiming
Focus
U-Def
L/A Eth
Tuning
Result
Press function key 1 x shortly
1
1
Briefly press the function button (
P
) once
✓
The device executes the respective function. Without the button being pressed,
the device automatically switches to read mode after 60 seconds.
3.
To manually end (cancel) a function, press the function button (
P
) again and hold
for 3 seconds.
Ready
5
0
7
0
1
2
0
2
0
0
3
0
0
Light
Test
Aiming
Focus
U-Def
L/A Eth
Tuning
Result
Press function key 3 seconds
1
1
Press the function button (
p
) for 3 seconds
✓
The device is ready for reading and is waiting for a read cycle.
NOTE
If the user does not press the function button (
p
) for 3 seconds, after 20 seconds
of cyclically lighting the LEDs, the device automatically exits the third display level
and returns to operational use.
7.4
Initial commissioning
The device is adjusted to the application using the SOPAS ET configuration software.
The default factory settings of the device are the starting point. The default parameter
values (configuration data) in the working memory of the device can be modified. For
this purpose, you can independently create an application-specific parameter set in
SOPAS ET and change it if required. You then load the current parameter set to the
permanent parameter memory of the device.