![SICK Lector61 Series Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/sick/lector61-series/lector61-series_operating-instructions-manual_1264266040.webp)
6.5.3
Wiring the data interface
Wiring the Internet interface
1.
Connect the device to the Ethernet connection of the computer via the adapter
cable.
2.
Set up communication via the SOPAS ET configuration software.
NOTE
The Ethernet interface of the device has an Auto-MDIX function. This automatically
adjusts the transmission speed as well as any necessary crossover connections.
Wiring the serial data interface
NOTE
The serial data interface is available only as a host interface for this device.
The maximum data transmission rate for the serial interface depends on the length of
cable and on the type of interface.
Table 8: Data transmission rates and recommended maximum lengths of cable
Interface
Data transmission rate
Distance to the target computer
(host)
RS-232
Up to 19.2 kBd
Max. 15 m
38.4 kBd ... 57.6 kBd
Max. 5 m
115.2 kBd … 500 kBd
< 2 m
NOTICE
Risk of damage to the internal interface modules!
If the serial data interfaces are wired incorrectly, then electronic components in the
device could get damaged.
■
Observe the information on wiring.
■
Carefully check the wiring prior to switching on the device.
RS-232
2
3
4
Device
1
Host
TxD
RxD
GND
RxD
TxD
GND
Figure 23: Wiring of the RS-232 serial data interface
1
Device
2
...
4
Pin assignment: see RS-232 pin assignment for the respective device
NOTE
Activate the serial data interface type in the device using a configuration tool, e.g., the
SOPAS ET configuration software.
6
ELECTRICAL INSTALLATION
40
O P E R A T I N G I N S T R U C T I O N S | Lector61x
8024830/1FGB/2022-03-29 | SICK
Subject to change without notice