3
R
emove approx
.
10
cm
(
4
in
)
of the cable mantle
,
strip approx
.
1
cm
(
0
.
4
in
)
of insulation from the ends of the individual wires
4
I
nsert the cable through the cable gland into the sensor
5
L
ift the opening levers of the terminals with a screwdriver
(
see
following illustration
)
F
ig
.
8
:
C
onnection steps
5
and
6
6
I
nsert the wire ends into the open terminals according to the wiring
plan
7
P
ress down the opening levers of the terminals
,
you will hear the
terminal spring closing
8
C
heck the hold of the wires in the terminals by lightly pulling on
them
9
T
ighten the compression nut of the cable entry
.
T
he seal ring must
completely encircle the cable
10
I
f necessary
,
carry out a fresh adjustment
11
S
crew the housing cover on
T
he electrical connection is
fi
nished
.
5
.
3
W
iring plan
,
single chamber housing
T
he following illustrations apply to the non
-
E
x as well as to the
EE
x
-
d
version
.
16
LBV
310
• -
R
elay
(
DPDT
)
5
C
onnecting to power supply
35919
-
EN
-
091126
Содержание LBV 310
Страница 1: ...D F GB S B E T R I E B S A N L E I T U N G LBV 310 Relais DPDT EN ...
Страница 31: ...ø 34 mm 1 34 178 mm 7 01 Abb 29 Temperaturzwischenstück LBV 310 Relais DPDT 31 9 Anhang 35919 DE 091125 ...
Страница 33: ...GB O P E R AT I N G I N S T R U C T I O N S LBV 310 Relay DPDT ...
Страница 62: ...ø 34 mm 1 34 178 mm 7 01 Fig 29 Temperature adapter 30 LBV 310 Relay DPDT 9 Supplement 35919 EN 091126 ...
Страница 63: ...LBV 310 Relay DPDT 31 9 Supplement 35919 EN 091126 ...