Operating Instructions
Chapter
5
IOLSHPB-P3104R01
2010-07-16
© SICK AG • Industrial Sensors • Germany • Subject to change without notice
59
Commissioning and operation
OUT process data
Assignment
“IOLM Status” byte 0
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reserved
0
0
0
0
0
0
0
0
“IOLM Status” byte 1
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Digital ouput states
Reserved
Port4 Port3
Port2
Port1
X
X
X
X
X
X
X
X
“IOL_I/O__4/_1 byte”
byte 0
See IOLD manufacturer description
“IOL_I/O__2/_8 byte +
dev prm” Byte 0
“IOL_I/O__2/_8 byte +
dev prm” byte 1
“IOL_I/O__2/_8 byte +
dev prm” byte 2
“IOL_I/O__2/_8 byte +
dev prm” byte 3
“IOL_I/O__2/_8 byte +
dev prm” byte 4
“IOL_I/O__2/_8 byte +
dev prm” byte 5
“IOL_I/O__2/_8 byte +
dev prm” byte 6
“IOL_I/O__2/_8 byte +
dev prm” byte 7
See IOLD manufacturer description
The background color of the individual process data bytes and the background color of the
individual bits is intended to illustrate the relationship between the process data and the
individual modules.
Note