Operating Instructions
Chapter
5
IOLSHPB-P3104R01
2010-07-16
© SICK AG • Industrial Sensors • Germany • Subject to change without notice
51
Commissioning and operation
GSD modules
IO-Link-mode
Meaning
Note
IOL_I/O__2/_8 byte
COM mode
2 byte IN
8 byte OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I/O__4/32 byte
COM mode
4 byte IN
32 byte OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I/O__32/4 byte
COM mode
32 byte IN
4 byte OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I/O__32/32 byte
COM mode
32 byte IN
32 byte OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I__8 bit + dev prm
COM mode
8 bits IN
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I__16 bit + dev prm
COM mode
16 bits IN
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I__32 bit + dev prm
COM mode
32 bits IN
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I__8 byte + dev prm
COM mode
8 byte IN
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I__32 byte + dev prm
COM mode
32 byte IN
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_O__8 bit + dev prm
COM mode
8 bits OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_O__16 bit + dev prm
COM mode
16 bits OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_O__32 bit + dev prm
COM mode
16 bits OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_O__8 byte + dev prm
COM mode 8
byte OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_O__32 byte +
dev prm
COM mode
32 byte OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I/O__8/_8 bit + dev
prm
COM mode
8 bits IN
8 bits OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I/O_16/16 bit + dev
prm
COM mode
16 bits IN
16 bits OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I/O_32/32 bit + dev
prm
COM mode
32 bits IN
32 bits OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I/O__4/_1 byte + dev
prm
COM mode
4 byte IN
1 byte OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I/O__2/_8 byte + dev
prm
COM mode
2 byte IN
8 byte OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I/O__8/_2 byte + dev
prm
COM mode
8 byte IN
2 byte OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I/O__4/32 byte + dev
prm
COM mode
4 byte IN
32 byte OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I/O_32/_4 byte + dev
prm
COM mode
32 byte IN
4 byte OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
IOL_I/O_32/32 byte +
dev prm
COM mode
32 byte IN
32 byte OUT
This module is used to operate an IOLD
in COM mode.
“Own” PD
PD-PCP 4 words
–
This module is an acyclic channel in the
process data.
(4 words IN/4 words OUT)
“Virtual” module,
“Own” PD
PD-PCP 6 words
–
This module is an acyclic channel in the
process data.
(6 words IN/6 words OUT)
“Virtual” module,
“Own” PD