Output voltage in ON state
Uv - 2 V DC … Uv (max. voltage drop ≤ 2 V DC)
Table 24: Mechanical data
Dimensions (W x H x D)
see "Safety switch dimensional drawings",
page 42
see "Actuator dimensional drawings",
page 43
see "Dimensional drawings of the mounting
bracket", page 44
Material
Safety switch housing
Retaining ball
Actuator tongue
Plug connector
Vistal® (fiberglass-reinforced thermoplastic)
Stainless steel
Stainless steel
Stainless steel
Weight
Power to release safety switch
480 g
Power to lock safety switch
535 g
Flexible actuator
90 g
Rigid actuator
75 g
Mechanical service life
1 × 10
6
switching operations
Table 25: Ambient data
Enclosure rating
IP65 (IEC 60529)
IP67 (IEC 60529)
IP69K (IEC 20653)
Ambient operating temperature
–20 °C … +55 °C
Storage temperature
–25 °C … +70 °C
Relative humidity
10 - 95% at 40 °C (IEC 60068)
Vibration resistance
1 mm / 10 Hz … 55 Hz (IEC 60068-2-6)
Shock resistance
30 g, 11 ms (EN 60068-2-27)
EMC
In accordance with IEC/EN 61326-3-1,
IEC/EN 60947-5-2, IEC/EN 60947-5-3 and
EN 300330
12.2
Classification according to ZVEI, CB24I
Table 26: Enable inputs for OSSDs (In1, In2)
Sink (this device)
C0
Compatible source
C2, C3
Table 27: Output OSSDs (OSSD1, OSSD2)
Source (this device)
C2
Compatible sink
C1, C2
Table 28: Application diagnostic output (Out AUX)
Source (this device)
C0
Compatible sink
C1, C2, C3
12.3
Connecting cables
Requirements for the connecting cables
Recommended cable type = LIYY 8 x 0.25 mm² or 5 x 0.34 mm²
TECHNICAL DATA
12
8020562/2022-07-07 | SICK
O P E R A T I N G I N S T R U C T I O N S | flexLock
41