Figure 13: Mounting using the optional mounting bracket
Minimum requirement on the screws for mounting the mounting bracket
•
Size: M6
•
Stainless steel screws: A2-70 or higher
•
Tightening torque: 5 Nm
•
Apply at least a medium-strength, material-bonded screw adhesive.
•
Screws are protected against manipulation, e.g., with screw covers. The mounting
bracket cannot be removed.
5.4
Mounting the actuator
Approach
1.
Select a position for the actuator on the movable physical guard. Select the
position in such a way that the actuator is inserted into the safety switch when the
movable physical guards closes.
For flexible actuators, the actuator tongue can be rotated in 90° increments if
necessary. To do so, press and rotate the actuator tongue in the actuator.
2.
Attach the actuator to the movable physical guard.
Minimum requirement for mounting screws
°
Design: Use one way screws to make unauthorized removal of the actuator
difficult (manipulation protection).
°
Quantity: 2
°
Size
Actuator
Size
Flexible
M5 × 25 (or longer)
Rigid
M5 × 14 (or longer)
°
Strength class: Class 8.8 or higher (stainless steel screws: A2-70 or higher).
°
Tightening torque: 5 Nm
3.
Apply at least a medium-strength, material-bonded screw adhesive.
4.
Close mounting holes with protective caps.
MOUNTING
5
8020562/2022-07-07 | SICK
O P E R A T I N G I N S T R U C T I O N S | flexLock
23
Subject to change without notice