Minimum requirement for mounting screws
°
Number: 4
°
Size: M5 × 25 (or longer)
°
Strength class: Class 8.8 or higher (stainless steel screws: A2-70 or higher).
°
Tightening torque: 5 Nm
3.
Apply at least a medium-strength, material-bonded screw adhesive.
4.
Place the protective cap at a 45° angle to the mounting hole.
Figure 11: Put on protective cap.
5.
Turn in protective cap and press down firmly. Use tool to press down if necessary.
Figure 12: Screw in protective cap and press down firmly.
6.
Repeat steps 4 and 5 for all protective caps.
Complementary information
The safety switch can be mounted on an aluminum profile using the optional mounting
bracket.
5
MOUNTING
22
O P E R A T I N G I N S T R U C T I O N S | flexLock
8020562/2022-07-07 | SICK
Subject to change without notice