Product description
3.6.10
Connection of sensors to the UE410-MU/UE410-XU
•
The allocation of the outputs X1 to X2 to the inputs I1 to I4 depends on the selected
input circuit function.
•
The functions of logic paths A and B can be set independently of each other.
Warning!
Unused inputs must be bridged as per the state shown!
=
Connect the sensors (type depending on the switch position) in accordance with
Tab. 18.
Program
Inputs of logic path A
Inputs of logic path B
0
Module inactive
Dual-channel non-isolated
semiconductors
U
B
-I3
U
B
-I4
Dual-channel equivalent
N/C contact
cross-circuit detecting
synchronisation time
monitoring 1500 ms
X1-I1
X2-I2
Dual-channel N/C contact,
three-wire
U
B
-I3
U
B
-I4
1
Four-wire
cross-circuit detecting
(e.g. cross-circuit detecting
switching mats)
X1-I1
X2-I2
Single-channel N/C contact
U
B
-I3
U
B
-I4
Dual-channel non-isolated
semiconductors
U
B
-I3
U
B
-I4
Dual-channel
complementary N/C
contact
cross-circuit detecting
synchronisation time
monitoring 1500 ms
X1-I1
X2-I2
Dual-channel N/C contact,
three-wire
U
B
-I3
U
B
-I4
2
Dual-channel
complementary N/C
contact
cross-circuit detecting
synchronisation time
monitoring 1500 ms
X1-I1
X2-I2
Single-channel N/C contact
U
B
-I3
U
B
-I4
Notes