Product description
The devices listed in the following can be connected to the UE410-MU and the modules
connected to it:
•
emergency stop pushbuttons
•
pressure sensitive mats
•
two-hand controllers
•
safety switches
•
non-contact safety switches (e.g. RE300, T4000 Compact, IN4000)
•
single-beam photoelectric safety switches (e.g. L21, L41)
•
safety light curtains and multiple light beam safety devices (e.g. MSL, miniTwin,
C/M2000, C/M4000)
•
safety laser scanners and safety camera systems (e.g. S300, V300, S3000)
Typical applications such as muting and OR links can be implemented simply, depending
on the setting of the program switch. If additional inputs or outputs are required, the
UE410-MU can be supplemented with a UE410-XU input/output extension module and/or
one or several UE410-8DI input extension modules.
If relay outputs are required, these can be implemented with the UE410-2RO/UE410-4RO
output modules.
3.2.2
UE410-GU main module
The UE410-GU is a main module that can be used as an alternative to the UE410-MU. As
in the UE410-MU, the system configuration for the entire Flexi Classic system is saved in
the UE410-GU. The UE410-GU makes possible a global emergency stop function for sev-
eral stations connected together that must each be equipped with a UE410-GU. A local
emergency stop is also possible on each UE410-GU.
The UE410-GU has 4 safety inputs (I1-I4), 1 semiconductor output (Q1), 1 output for a
lamp for “Global emergency stop status” and “Reset required” (Q2), 2 test outputs (X1, X2)
and 2 inputs and 2 outputs for the global emergency stop function (I
P
, I
N
, O
P
and O
N
). The
safe control inputs I5 and I6 are used to connect external device monitoring and a reset
button. The 9 available programs can be set using a rotary switch and make it possible to
connect a variety of safety components.
The following devices can be connected to the UE410-GU:
•
emergency stop pushbutton
•
safety switch
•
non-contact safety switches (e.g. RE300, T4000 Compact)
•
single-beam photoelectric safety switches (e.g. L21, L41)
•
safety light curtains and multiple light beam safety devices (e.g. MSL, miniTwin,
C/M2000, C/M4000)
•
safety laser scanners and safety camera systems (e.g. S300, V300, S3000)
If additional inputs are required, the UE410-GU can be expanded with one or more input
extension modules UE410-8DI.
The UE410-GU can also be expanded with a UE410-XU. This module does not act on the
global emergency stop.
If relay outputs are required, these can be implemented with the UE410-2RO/UE410-4RO
output modules.
The UE410-GU does not support all data sets from all gateways.
Note