Meaning of the LEDs L/A1 and L/A2
Status LED
Description
OFF
No supply voltage or
No Ethernet connection
Green
Ethernet connection established
Yellow
Interface port blocked
Green blinking
Data transmission TxD/RxD
Yellow blinking
Data collision
3.7
AFS60/AFM60 EtherCAT
®
, device handling in the network
Dear valued customer,
please download the operating instructions and the ESI file (XML) for the AFS60/
AFM60 EtherCAT® from our homepage
. For this, please enter the seven-
digit part number of your encoder directly in the field “Search” on the welcome page.
Then please click on the searching result and you will be forwarded to all information
and files for your product.
The following encoder feature can be configured via the hardware:
•
Preset function
The following measures are necessary in order to run one of these functions
•
Remove screw-on cap from the back of the encoder
GND
2
3
1
4
10–30 V DC
WARNING
DO NOT
USE
x10
x100
x1
STAT
NMOD
L/A1
L/A2
Port
P
1
ort 2
Encoder
a
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
DEC Switches out of operation
Preset
push-button
3.7.1
Preset button hardware (see manual 8015235 for software)
The encoder is set to a special pre-defined value when the PRESET function is activated
by pressing the Preset button. The works default value is zero (0).
•
Remount screw cap.
Screw cap tightening torque: 0.8 Nm
MOUNTING INSTRUCTIONS
8015236/1EF3/2021-12-02 | SICK
M O U N T I N G I N S T R U C T I O N S | AFS/AFM60 EtherCAT
®
15
Subject to change without notice