![SICK deTem4 Core Ex Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/sick/detem4-core-ex/detem4-core-ex_operating-instructions-manual_1264385054.webp)
Technical data for sender
Table 10: Technical data for sender
Minimum
Typical
Maximum
Wavelength of sender
Near-infrared (NIR), invisible
Effective aperture angle (EAA)
1)
2.5°
Current consumption
50 mA
Power consumption
1.44 W
1)
Distance between sender and receiver D ≥ 3 m.
Technical data for receiver
Table 11: Technical data for receiver
Minimum
Typical
Maximum
Current consumption
150 mA
Power consumption
4.32 W
Output signal switching devices (OSSDs)
Type of output
2 PNP semiconductors, short-circuit protected
1)
, cross-
circuit monitored
Duration of OFF state
100 ms
Switch-on delay
3 × response
time
Output voltage for ON state (HIGH)
2)
(U
V
– 2.25 V) … U
V
Output voltage for OFF state (LOW)
2)
3)
0 V … 2.0 V
Output current for ON state (HIGH)
300 mA each
Leakage current of the OSSDs
2 mA each
Load capacity
2.2 µF
Load inductance
2.2 H
Test pulse data
4)
Test pulse width
150 µs
300 µs
Test pulse rate
3 s
–1
5 s
–1
10 s
–1
Permissible cable resistance
Between device and load
5)
2.5 Ω
Supply cable
6)
1 Ω
1)
Applies to the voltage range between -30 V and +30 V.
2)
According to IEC 61131-2.
3)
The specified values are the switching voltage passed to the device. If higher voltages are impressed from
the outside, the maximum value of 2.0 V can be exceeded.
4)
When active, the outputs are tested cyclically (brief LOW). When selecting the downstream controllers,
make sure that the test pulses do not result in deactivation when using the above parameters.
5)
The cable resistance of the individual wires to the downstream controller must not exceed this value, to
ensure that a cross-circuit between the outputs is safely detected. (Observe standard IEC 60204-1 too.)
6)
The supply cable must not be used to connect other loads with the exception of the sender.
Operating data
Table 12: Operating data
System connection
Male connector, M12, 5-pin
Length of cable
1)
50 m
12
TECHNICAL DATA
54
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core
8020453/14Q7/2020-04-27 | SICK
Subject to change without notice