![SICK CLV61 DualPort Series Скачать руководство пользователя страница 61](http://html.mh-extra.com/html/sick/clv61-dualport-series/clv61-dualport-series_operating-instructions-manual_1264234061.webp)
12
Technical data
NOTE
The relevant online data sheet for your product, including technical data, dimensional
drawing, and connection diagrams can be downloaded, saved, and printed from the
Internet:
•
Please note: This documentation may contain further technical data.
12.1
Features
Table 16: Technical data features
CLV610
CLV612
CLV615
Work area
Mid range
Short Range
Long Range
Scanning methods
Line scan or raster scan
1)
, type-dependent
Sensor type
Line scanner or raster scanner, type-dependent, identifier
Orientation of viewing
window
Front or side
2)
3)
, type-dependent, identifier
On the side
2)
3)
Aperture angle
≤
50°
Optical focus
Fixed focus
Code resolution
0.2 mm ... 1.0 mm
0.1 mm ... 0.2 mm
0.35 mm ... 0.5 mm
Reading ranges
see "Reading field diagrams (working ranges)", page 64
Scanning frequency
400 Hz ... 1,000 Hz
Light source
Laser diode, visible red light (
λ
= 655 nm)
Light spot
Circular
MTTF (laser diode)
40,000 hours at 25 °C
MTBF
100,000 hours
Laser class
Class 2 according to EN/IEC 60825-1:2014. Identical laser class for
issue EN/IEC 60825-1:2007.
Conforms to 21 CFR 1040.10 except for deviations per Laser Notice
No. 50 of June 24, 2007, and subsequent versions.
Laser power
P = 1.5 mW maximum, P < 1.0 mW average
Laser pulse duration
< 300 μs
1)
Front viewing window: 8 lines, grid height approx. 15 mm at reading distance 200 mm.
Side viewing window: 8 lines, grid height approx. 15 mm at reading distance 185 mm.
2)
Side viewing window: Light emission at 105° relative to the longitudinal axis of the device.
3)
12.2
Performance
Table 17: Technical data for performance
CLV610
CLV612
CLV615
Readable code struc‐
tures
1D codes
Bar code types
Code 39, Code 128, Code 93, Codabar, UPC / GTIN / EAN, 2/5 Inter‐
leaved, Pharmacode
Print ratio
2:1
...
3:1
TECHNICAL DATA
12
8017840/19OF/2021-10-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | CLV61x
61
Subject to change without notice