Device Description
Device layout
39.
5
40.
7
36.
3
4
38.
8
All dimensions in mm
207
1
1
7
5
8
6
4
2
3
9
9 ß
ß
31
59.4
à
à
175.2
192.5
7.1
7.1
24.
5
49.
5
28.
5
4
23.
5
32.5
31.7
26.2
26.2
59.4
(31)
24
14
CDF600-2200: View and dimensions
Legend:
1
Elongated drill hole (2 x), length 10 mm, unpainted, for mounting
with M6 screw
2
"P2 PROFINET" connection, 4-pin M12 female connector, D-coded
3
"P1 PROFINET" connection, 4-pin M12 female connector, D-coded
4
"USB" connection, 5-pin micro-B female connector, for configuration
and diagnostics, behind screw-mounted cover
5
"Mode" rotary encoding switch, for operating mode, behind screw-
mounted cover
6
"EXT. IN 1" connection, 5-pin M12 female connector, A-coded
7
"POWER" connection, 5-pin M12 male connector, A-coded
8
"DEVICE" connection, 15-pin D-SUB HD female connector with seal
9
LED (6 x), status indicator (POWER, EXT. IN 1, SF, BF, P1 LNK/ACT,
P2 LNK/ACT)
ß
Screw (Torx T8), captive (2x), for cover
Elongated drill hole (2 x), length 15 mm, unpainted, for alternative
mounting with M6 screw
Optical status indicators
Indication
LED
Status
Status
POWER
–
OFF
Fieldbus module without supply voltage
Green
Flashes
cycli-
cally
Sequence:
Once:
Only in operating mode 0 (proxy):
Following startup, the fieldbus module searches for the ID sensor that supports proxy mode.
Twice
:
The position of the rotary coding switch “Mode” was changed during operation.
This has no influence on active operation.
Following a restart, the fieldbus module then works in the operating mode that the new position of the
rotary encoding switch presents.
3 times
:
Transparent operation of fieldbus module (operating mode F) for firmware update of the ID sensor.
No communication with PROFINET IO.
O
Green
ON
Fieldbus module ready following start and initialization.
Operating mode 0 (proxy):
Communication established with ID sensor that supports proxy mode. The fieldbus module is operational.
Operating mode 2 or 4 (gateway):
The fieldbus module is operational.
EXT. IN1
–
OFF
No power supply to external input 1
1)
O
Yellow
ON
Power supply to external input 1
1)
SF
–
OFF
Fieldbus module without internal error
O
Red
ON
Operating mode 0 (proxy): Following startup, the fieldbus module searches for the ID sensor that supports
proxy mode
BF
–
OFF
Data exchange between fieldbus module (IO device) and IO controller via PROFINET IO possible
O
Red
ON
No connection between fieldbus module (IO device) and IO controller.
Possible causes:
– No electrical connection between fieldbus module and PROFINET IO
– IO controller not available or switched off
– Wrong PROFINET name
– Wrong GSDML file used
– Wrong GSDML module selected
Red
Flashes
cycli-
cally
Frequency 0.5 Hz
Possible causes:
– Parameterization error on IO controller (e.g., incorrect ID for IO device), no data exchange
– Error on IO controller affecting configuration with modules, no data exchange
P1 LNK/ACT
2)
–
OFF
Fieldbus module not connected to any active network; no data traffic possible
P1 LNK
O
Green
ON
Fieldbus module connected with active network, e.g. with an Ethernet switch (switched-on)
P1 ACT
O
Orange
ON
LED flickers when the fieldbus module is sending or receiving data
P2 LNK/ACT
2)
–
OFF
Fieldbus module not connected to any active network; no data traffic possible
P2 LNK
O
Green
ON
Fieldbus module connected with active network, e.g. with an Ethernet switch (switched-on)
P2 ACT
O
Orange
ON
LED flickers when the fieldbus module is sending or receiving data
SF = system failure, BF = bus failure.
1) Regardless of the logic assigned to the input via the SOPAS ET configuration software of the ID sensor.
2) There are 2 separate LEDs under the display window
O
= illuminated;
= flashing