Fig. 8:
Parameter
Assignment
tab
4.4.4
Configuring the A3M60 Basic
►
Double-click the encoder icon.
The
Properties
window is opened.
►
Select the
Parameter Assignment
tab.
A3M60 Basic
The A3M60 Basic is supplied with the following parameters:
code sequence clockwise
class 2 functionality = activated
no scaling
resolution per revolution = 8,192
total resolution = 67,108,864
Code sequence
►
Configure the
Code Sequence
parameter to
Clockwise
or
Counterclockwise.
Scaling
►
Configure the
Scaling
parameter to the value
Enable
if you want to configure a lower
resolution.
►
Using the
Measuring Units per Revolution
parameter configure the resolution per
revolution.
►
Using the
Total Measuring Range
parameter configure the total resolution.
Compiling
►
Compile the data and load the data into the control system.
The new values are applied.
Both LEDs on the A3M60 Basic illuminate green.