11
UL Satisfaction Ratings
The total control output current and ambient temperature will be retricted as follows
depends on the number of sensors (proximity switch) connected to the programmable
controller.
Up to 3 units:
Input
12 - 24 V dc, max. 1.02 A, Class 2
Output
12 - 24 V dc, max. 0.45 A, Class 2
Maximum surround air Tempe55°C.
Up to 8 units:
Input
12 - 24 V dc, max. 1.02 A, Class 2
Output
12 - 24 V dc, max. 0.8 A, Class 2
Maximum surround air Tempe50°C.
Up to 16 units:
Input
12 - 24 V dc, max. 1.02 A, Class 2
Output
12 - 24 V dc, max. 0.8 A, Class 2
Maximum surround air Tempe45°C.