The device is structured in different slots.
Slot 1 represents the PROFINET coupler.
Slots 2 to 17 represent the connected devices as shown in the following figure.
2
3
4
17
1
WI180C-PN supports up to 16 device modules. The following products are supported:
Table 5: Supported products
Supported products
Product description
Note
WLL180T-L*
WLL180T-M*
Fiber amplifier base unit
•
WLL180T base unit can
only be placed as module
#1 (left-most on DIN rail)
•
No extra power supply to
WLL180T device required
WLL180T-E*
WLL180T-F*
Fiber amplifier expansion unit
•
WLL180T base unit can
only be placed as module
#2 … #16
•
No extra power supply to
WLL180T device required
OD1 on one input of AOD1-M
Displacement sensor
evaluation base unit
•
For each AOD1 unit
plugged, the total number
of pluggable modules
decreases by one (max. 8
AOD1 units possible)
•
If AOD1 and WLL180T are
used in combination with
WI180C-PN, all WLL180T
devices must be placed left
from the AOD1
•
AOD1-M base unit can only
be placed as Module #1/2
(left-most on DIN rail)
•
Power supply to AOD1-M
device required
OL1 on one input of AOD1-M
Displacement sensor
evaluation base unit