Index No.
Function
Further
description
R/W
Length
(bytes)
Contents/Meaning
0xnn79
Baud rate
R/W
2
0: No sensor head
1: 9.6k
2: 19.2k
3: 38.4k
4: 57.6k
5: 115.2k
6: 230.4k
7: 312.5k
8: 460k
9: 500k
10: 625k
11: 833k
12: 921k
13: 1250k (default: 9)
OL1 parameters
0xnn86
Moving average
R/W
2
1 ... 128 (sample points)
0xnn87
Measurement
type
R/W
2
0: Edge positive
1: Edge negative
2: Width
0xnn88
Sampling rate
R/W
2
0: 500 us (fixed)
0xnn8F
Measuring direc‐
tion
R/W
2
0: Top to bottom
1: Bottom to top
0xnn90
Zeroing value
R/W
2
-9999 ... 5000 (default: 0)
0xnn98
Sensitivity
R/W
2
0: Min Sense
1: 2nd Sense
2: 3rd Sense
3: 4th Sense
4: Max Sense
5: Adjusted
0xnnC8
Store zero-reset
W
2
0xnnC9
Cancel zero-reset
W
2
0xnnD4
Factory reset
W
2
3: Execute (All settings except Baud rate are reset
to defaults)
Module KTL180
0xnn00
Products series
b15-12 Manufacturer
b11-8 Categories
b7-0 Family
R
2
0x1111 (1 output model) / 0x1112 (2 outputs
model)
1: SICK
1: Fiber amplifier
11: KTL180 1 output
12: KTL180 2 outputs
0xnn01
Product type
R
2
17: WLL180T
0xnn02
Firmware version
R
2
0x0100
0xnn03
Protocol version
R
2
1
0xnn04
Product Revision
R
2
1
0xnn05
Vendor name
R
2 ... 16
"SICK AG"
0xnn06
Actual product
type name
R
2 ... 32
Actual product type name
0xnn07
Product ID
R
2 ... 16
Actual product type code
0xnn08
User Tag name
R/W
2 ... 32
Blank space (default)
7
OPERATION
26
O P E R A T I N G I N S T R U C T I O N | WI180C-PN
8023551/11HP/2019-03-07 | SICK
Subject to change without notice