If no voltage is applied at the input after the OSSDs have been switched off, the safety
laser scanner changes to the locking state and does not switch the OSSDs back to the
ON state.
Signal level
For some non-safe output signals, you can select whether the signal is output with
HIGH or with LOW:
•
Setting
Hi
: The output is normally in LOW state. If the signal is active, the output
switches to HIGH state.
•
Setting
Lo
: The output is normally in HIGH state. If the signal is active, the output
switches to LOW state.
Further topics
•
7.10
Monitoring cases
Overview
Figure 56: Monitoring cases
1
Settings for the whole monitoring case table
2
Configured field sets
3
Settings for the individual monitoring case
4
Input conditions for a monitoring case
5
Field set in the monitoring case and in the cut-off path
6
Cut-off paths
7