Multiple sampling
and
Object resolution
DANGER
Hazard due to lack of effectiveness of the protective device
Persons or parts of the body to be protected may not be recognized or not recognized in
time in case of non-observance.
A higher multiple sampling increases the response time.
b
Make a note of the new response time of the safety laser scanner in Safety
Designer.
b
Adjust the minimum distance from the hazardous point to the new response time.
Safety Designer initially uses multiple sampling and the object resolution of the moni‐
toring plane for the fields.
If necessary, define multiple sampling and the object resolution for each field individu‐
ally.
1.
Select multiple sampling.
✓
Multiple sampling indicates how often an object has to be scanned before the
safety laser scanner responds.
2.
Select object resolution.
✓
The object resolution defines the size that an object must be to allow it to be
reliably detected.
Name
Assign a unique name for each field set.
1.
Select the field set to be edited.
2.
Enter the name of the field set.
7.8.2
Creating field set templates
If you require the same combination of fields a number of times, you can create a field
set template.
You can edit field set templates using the
Manage field set templates
tool.
Example: you define a field set template with protective field, warning field1 and warn‐
ing field2.
Figure 50: Field set template
Approach
1.
Click on
Add field set template
.
2.
Enter the name for the template.
CONFIGURATION
7
8023152/1G5N/2022-06-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
87