13.3
Data sheet
13.3.1
outdoorScan3 Core I/O
Features
Table 25: Features
outdoorScan3 Core I/O
Devices with a max. protec‐
tive field range of 4.0 m
≤ 4.0 m, details:
Warning field range
Devices with a max. protec‐
tive field range of 4.0 m
≤ 40 m
Distance measurement range
Devices with a max. protec‐
tive field range of 4.0 m
≤ 40 m
Fields
≤ 8
Simultaneously monitored
fields
≤ 4
Field sets
≤ 8
Monitoring cases
≤ 2
Scanning angle
275° (–47.5° to 227.5°)
50 mm, 70 mm
Angular resolution
Devices with a max. protective field range of 4.0 m
Scan cycle time 40 ms 0.39°
Devices with a max. protec‐
tive field range of 4.0 m
≥ 90 ms, details:
see "Response times", page 137
Devices with a max. protec‐
tive field range of 4.0 m
40 ms
Generally necessary protective field supplement (TZ = tolerance zone of the safety laser
scanner)
Devices with a max. protec‐
tive field range of 4.0 m
65 mm
Additional supplement
Z
R
for reflection-based meas‐
urement errors
350 mm
Deviation from ideal flatness
of scan field at 5.5 m
≤ ± 100 mm
Distance of mirror rotational
axis (zero point of x and y
axis) to rear side of device
56 mm
Distance between center
point of scan plane and top
edge of the housing
40 mm
Multiple sampling
2 to 16
13
TECHNICAL DATA
132
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
8023152/1G5N/2022-06-28 | SICK
Subject to change without notice