Installation instructions
Note: The kit supplied in the scope of delivery is designed for vertical installation to a stable wall.
For installation on other types of walls, you will need the appropriate fittings (not included in the
scope of delivery). Please make sure that heating panel can be securely installed. We highly
recommend having the panel installed by a qualified electrician or
SHX
authorised installation
technician. The heater must be installed at least 20 cm away from all items, walls, etc. A space of
at least 20 cm must be kept to the floor, and a distance of at least 20 cm above the heater must
also be kept.
SAFETY INFORMATION FOR INSTALLATION
The heating panel can be mounted on walls or other vertical surfaces.
Please note the following points for installation:
1. Make sure that the wall or vertical surface you mount the heating panel on can carry the weight
of the appliance.
2. To avoid overloading the circuit, do not connect the panel to a circuit to which other devices are
already connected.
3. Do not mount the heating panel directly under a wall socket, since the strong heat development
takes place above the panel and the socket could be damaged.
4. A space of at least 50 cm should be kept above, below and to the sides of the heating panel
and other objects (window sill, power socket, etc.). A space of at least 1
–2 metres should be kept
to large items and flammable objects.
5. Make sure that there is no material in the immediate surrounding of the heating panel that can
deform or discolour when the temperature is above 100°C.
6. In order not to impair the heating efficiency, do not position any furniture or other objects in front
of the heating panel.
7. Never install the cable behind the panel.
NOTE
We recommend that assembly be carried out by two people in order
not to damage the heating panel.