TECHNICAL SPECIFICATIONS  

DESIGN: 

Positive Displacement; Fix Ratio (non-adjustable) 

POWER SOURCE: 

Potable Water 

MATERIALS OF CONSTRUCTION: 

Acetal Copolymer, EPDM, Santoprene, Silicone, 316 Stainless Steel-
FDA sanctioned, NSF listed 

TEMPERATURE LIMITS: 

34 - 120

°

F  [2-45

°

C] 

DIMENSIONS 

7.6" x 5.2" x 5.7"  [19.3 x 13.2 x 14.47 cm] 

WEIGHT: 

2.2 lbs.  [1 kgs] 

DISPLACEMENT: 

6.5 oz./ stroke  [190cc] (concentrate & water) 

FLOW RATE: (1 valve) 

2-3 oz. [60-90cc] per sec. / varies with system design and 
concentrate  

OPERATING PRESSURE: 

50 PSI. [3.4 bar] MAX. / 25 PSI. [1.7 bar] MIN. 

ACCURACY: 

± 3% of available ratio 

SOLD OUT: (available) 

Automatic B-I-B Vacuum Shut-off @ 18-22 in. Hg. [48-61 kPa] 

SUCTION LIFT (Wet): 

25 in. Hg. [85 kPa] (minimum) 

STANDARD FITTINGS: 

3/8" [10mm] Barb, Plastic 90

°

 configuration 

AVAILABLE FITTINGS: 

1/4" [6mm] , 3/8" [10mm], and 1/2" [13mm] barb, Plastic or 
Stainless Steel; Straight and/or 90

°

 configurations 

MODEL NUMBER MATRIX: 

  5000 

2XX 

- 01 (without shut-off) 

 

(Model)

  

-

 

(ratio*)

 

- 02 (with shut-off) 

AVAILABLE RATIOS: 

3.00 : 1 

(*30)  {Red dot} 

 

4.00 : 1 

(*40)  {Blue dot} 

 

4.20 : 1 

(*42) 

 

5.00 : 1 

(*50)  {Yellow  dot} 

 

5.30 : 1 

(*53) 

 

6.00 : 1 

(*60) 

 

Other ratios available, contact the factory for specific 
applications.  

 
 
 
 
 
 
 
 
 
 
 
 
 

 

«

 

ISO Certified Facility

 

             

R

a WICOR Company

 

 

COMPONENT

 

SHURflo reserves the right to update specifications, prices, or make substitutions.  

SHURflo 

«

 

5900 Katella Ave. 

Cypress, CA 90630 

(800) 854-3218  (562) 795-5200  

FAX  (562) 795-7564 

Shipping/UPS:

 5900 Katella Ave. 

          Bldg. B 

        Cypress, CA 90630 

SHURflo East 

52748 Park Six Court 

Elkhart, IN  46514-5427 

(800) 762-8094 
(574) 262-0478 

FAX  (574) 264-2169 

© 1998   Printed in USA

 

SHURflo Ltd.  

Unit 5 Sterling Park 

Gatwick Road, Crawley 

West Sussex, RH10 2QT 

United Kingdom 

+44 1293 424000 

FAX  +44 1293 421880 

 

Содержание Brix 94-260-01

Страница 1: ...f the proportioned liquids typically the incoming water eliminating the need for CO2 or electric power The Brix pump is designed with a vacuum shut off The vacuum shut off will automatically stop operation of the brix pump when the concentrate BIB container is completely evacuated by closing off the water inlet When a new BIB is installed the pump will automatically resume operation without the ne...

Страница 2: ...e POWER SOURCE Potable Water MATERIALS OF CONSTRUCTION Acetal Copolymer EPDM Santoprene Silicone 316 Stainless Steel FDA sanctioned NSF listed TEMPERATURE LIMITS 34 120 F 2 45 C DIMENSIONS 7 6 x 5 2 x 5 7 19 3 x 13 2 x 14 47 cm WEIGHT 2 2 lbs 1 kgs OPERATING PRESSURE 50 PSI 3 4 bar MAX 25 PSI 1 7 bar MIN ACCURACY 3 of available ratio SOLD OUT Automatic B I B Vacuum Shut off 18 22 in Hg 48 61 kPa A...

Страница 3: ... years of experience in pump technology to provide a safe and reliable proportioning pump Every SHURflo pump is 100 tested for proper flow pressure and performance before it leaves the factory Although this tested design will provide years of trouble free and economical operation you should use care in installing your system ...

Страница 4: ...vacuated by closing off the inlet water When a new B I B is installed the pump will automatically resume operation without the need to prime the system BRIX pumps without a vacuum shut off option should be used with rigid sided containers like tanks or jugs Containers of this type must be vented Dashed lines indicate position of vacuum shut off when ordered The BRIX pump is available in exact rati...

Страница 5: ... damage to the pump may occur When multiple concentrates are plumbed to a post mix dispenser each pump s water outlet must have an individual line valve to open when that flavor is selected Bar Guns generally are restrictive therefore it is recommended that special Juice Guns be used Concentrate passages of standard bar guns are small and may become plugged with pulp or solids contained in some co...

Страница 6: ...ber in line prior to the dispenser The single line run lengths should be minimal to reduce backpressure Backpressure within teed outlet line should not exceed 32 psi 2 0 bar Pre mix valves with minimal full flow backpressure are commonly used with this type of configuration Teed systems should have a one way check valve plumbed after the concentrate outlet and before teeing into the water outlet l...

Страница 7: ...ich are highly viscous and or contain solids may be packaged with a connection that uses a less restrictive Q C D and 1 2 13mm I D tubing The length of tubing and vertical lift that a BRIX pump can accommodate at the concentrate inlet is dependent on the particular characteristics of the product Also colder concentrate temperatures adversely affect the systems inlet side due to the increase in vis...

Страница 8: ...line and plumb to the Sanitize port as shown on pages 2 or 3 Always use NSF listed high pressure braid tubing 3 8 or 1 2 10 or 13mm I D for pressurized lines and secure all connections with stainless steel inserted Oetiker clamps Tie wrap all tubing securely to prevent kinks and relieve stress on pump fittings Although it is recommended that line lengths are kept to a minimum it is a good idea to ...

Страница 9: ...tion 5 25 or equivalent 3 Clean five 5 gallon U S 19 liter bucket 4 Measuring cup 5 An adapter is needed to hold the Q C D fitting on the concentrate suction line open A connector cut from an empty bag will work SANITIZING PROCEDURE 1 Fill the bucket with four 4 gallons 15 14 l of warm water 120 180 F 48 82 C 2 Measure four 4 ounces cup 118cc of the liquid detergent and add to the water 3 Measure ...

Страница 10: ...e when the bags where filled Stand the box up on end and pull the connector up allowing air to rise up to the bag connector Install a Q C D and engage it on the bag connector opening the passage Slowly press the Q C D back down expelling the air until concentrate appears release the Q C D closing the connector This is referred to as burping the bag Pump stroke should be even time in both direction...

Страница 11: ...or for information Complete instructions are included with each kit 3 Reassemble each cartridge so that the valve support is not holding the valve open Lubricate the serrated surface of the valves and o rings with an NSF listed food grade lubricant Reinsert the appropriate valves into the housing turn back into position and tighten the screw Be aware that the valves may turn allowing the support t...

Страница 12: ...moved see SHURflo Service Bulletin 1046 Pumps that are returned to SHURflo that are not sanitized flushed will be dispositioned as a scrapped pump and will not be considered for testing repair or recondition When BRIX pumps are being returned to a service center please contact the appropriate location prior to shipment to initiate a Return Goods Authorization SHURflo manufactures the BRIX pump com...

Страница 13: ...Rflo East Elkhart IN or West Coast facility Cypress CA Package all returns carefully SHURflo will not be responsible for freight damage incurred during shipping to a service center Upon receiving a pump it will be tested per SHURflo s test criteria SHURflo s obligation under this warranty policy is limited to the repair or replacement whichever it deems advisable of the unit Pumps found not defect...

Страница 14: ...b Plastic 90 configuration AVAILABLE FITTINGS 1 4 6mm 3 8 10mm and 1 2 13mm barb Plastic or Stainless Steel Straight and or 90 configurations MODEL NUMBER MATRIX 5000 2XX 01 without shut off Model ratio 02 with shut off AVAILABLE RATIOS 3 00 1 30 Red dot 4 00 1 40 Blue dot 4 20 1 42 5 00 1 50 Yellow dot 5 30 1 53 6 00 1 60 Other ratios available contact the factory for specific applications ISO Ce...

Отзывы: