Caution! Performing a reset on either the Dante network
card or on the ULX-D receiver will interrupt the Dante
audio.
Tip: Prior to performing a factory reset, note the current
Dante network mode and IP settings. After a reset, the
Dante network mode reverts to SWITCHED, and the IP
address mode revert to AUTO.
Restoring Receiver and Dante Card Factory
Settings
Performing a reset from the receiver restores the factory
settings and configures the Shure Control and Dante IP
address mode to AUTO.
1. From the receiver menu: DEVICE
UTILITIES >
SYSTEM
RESET > RESTORE
DEFAULT
SETTINGS
2. Press ENTER to complete the reset.
Restoring the Dante Network Card Factory Settings
The Factory
Reset option within the Dante controller
restores the Dante card to the factory settings and
configures the Dante IP address mode to AUTO.
1. From the Dante controller, select a receiver and open
the Network
Config tab.
2. Click on Factory
Reset.
3. Allow the Dante controller to refresh before making
any additional changes.