Shure Incorporated
81/103
◦
◦
◦
◦
◦
◦
◦
◦
◦
◦
◦
Active
Mute
Solid Red
Off
External LED Control
*Not available for MX400R series gooseneck microphones
④
Mute Preference
Local Mute - Individual (default):
Each transmitter is muted individually.
Local Mute - All:
All transmitters mute when any transmitter is muted.
External Mute:
Transmitter audio is on, and muted from a 3rd-party controller.
⑤
RF Power
Determines the RF coverage of an access point.
Low:
25 ft (1mW)
Medium:
50 ft (3 mW)
Medium High:
100 ft (16 mW)
Max:
150 ft (80 mW)
⑥
Out of Range Alarm
When enabled, a transmitter will audibly beep when it is taken out of the RF coverage area. (Disabled by default.)
⑦
Back in Range Action
Transmitters can be set to automatically activate (default) or mute when they re-enter the RF coverage area.
⑧
Standby Mode
Local (default): Transmitter can individually be activated.
Global: All transmitters are activated at the same time from Standby mode.
⑨
Linking Preference
The Link procedure can be restricted to the control software by disabling the hardware Link button on the Networked
Charging Station. By default, the Link button is enabled.
⑩
Identity Preference
Determines the way the transmitter responds when it is identified from the control software:
Enabled:
Beeps with flashing LEDs
Disabled:
Flashing LEDs only (no sound)
⑪
Language
Determines the language of the control software.
⑫
Password Setup
The default password for the device is 'admin'. The following describes access rights for each logon:
Admin (default):
Full monitoring and editing access. The Admin can enable or disable the Tech- and Guest-level logon.