Shure Incorporated
49/55
AES67 or Dante Digital Output
Channel Count
5 total channels (4 independent transmit channels, 1 Automatic mixing transmit channel)
Sampling Rate
48
kHz
Bit Depth
24
Sensitivity
at 1 kHz, , -15
dB
Gain Setting
-21
dBFS/Pa
Maximum SPL
1 kHz at 1% THD, -15
dB
Gain Setting
115.2
dB SPL
Signal-To-Noise Ratio
Ref. 94 dB SPL at 1 kHz, -15
dB
Gain Setting
Cardioid
75
dB
Toroid
67
dB
Latency
Not including Dante latency
<1
ms
Self Noise
-15
dB
Gain Setting
Cardioid
19.2
dB SPL-A
Toroid
26.8
dB SPL-A
Dynamic Range
-15
dB
Gain Setting
Cardioid
96
dB
Toroid
90
dB SPL
Built-in Digital Signal Processing
Per Channel
Equalizer (4-band Parametric) , Mute, Gain (140
dB
range)
System
Automatic mixing, Low-Cut Filter (-12 dB/octave @150
Hz
)
Networking
Cable Requirements
Cat 5e or higher (shielded cable recommended)
Frequency Response
Frequency response measured from a distance of 2 feet (61 cm).