000 = 2400 (default)
001 = 4800
010 = 9600
011 = 19200
100 = 28800
101 = 38400
110 = 57600
111 = 115200
Change the baud rate according to your RS232 devices’ baud rate.
Beside the 3 Bit DIP switch , it is available to change the baud rate on the web browser. Login
TX and RX with their default IP (TX: 192.168.1.11; RX: 192.168.1.12) to modify the Baud Rate
which range from default 2400 to 115200.
When sending data, the IP address must be put as header (eg: If you need send “5A” from RX
to TX, the IP address of TX is 192.168.1.11, “CO A8 1 B” is the Hex format of IP address
192.168.1.11, then you should send “CO A8 1 B 5A”; if you need send “5A” from TX to RX, the
IP address of RX is 192.168.1.12, “CO A8 1 C” is the Hex format of IP address 192.168.1.12,
then you should send “CO A8 1 C 5A”;).
7. Firmware update
We provide the firmware to upgrade the units when it is necessary. Login TX and RX with their
default IP (TX: 192.168.1.11 ; RX: 192.168.1.12) on web browser to update the firmware.
Update firmware on TX
A. Connect TX and PC with a short Cat5e cable
B. Power on TX with adapter 5V 2A
C. Login TX with its default IP: 192.168.1.11, and user name: admin password: admin
D. Click “choose File” on the interface and find out the latest version firmware
E. Click “Upgrade”, the pressing will takes seconds, please DO NOT interrupt or power off
the units during the time.
Update firmware on RX
A. Connect RX and PC with a short Cat5e cable
B. Power on RX with adapter 5V 2A
C. Login TX with its default IP: 192.168.1.12
D. Click “choose File” on the interface and find out the latest version firmware