Attribute
Value
Name
Encoder Fault Steps
Index
0x2034
Subindex
0x00
Type
UNSIGNED16
Access
RW
Default Value
0xFFFF
Value range
0
0xFFFF
Units
CPR
Table 9-49 Encoder Fault Steps
9.2.24
Digital Inputs Configuration Object 0x2070
The object assigns the functionality for each configurable input.
The configurable inputs are IN1, IN2 and IN3, so the number of subindex is 3 and the “n” value in
table is in the range 1 – 3.
Attribute
Value
Name
Digital Inputs Configuration
Index
0x2070
Subindex
0x00
Type
RECORD
Access
RW
Default Value
0x03
Table 9-50 Digital Inputs Configuration
Attribute
Value
Name
Function of Digital Input n
Index
0x2070
Subindex
0x0n
Type
UNSIGNED16
Access
RW
Default Value
0x0001 (IN1), 0x0002 (IN2), 0x0800(IN3)
Value range
0x0000
0xFFFF
Table 9-51 Function of Digital Input n
Bit Value
Functionality
Description
0
0x0001 Negative limit switch
Used in some homing modes
1
0x0002 Positive Limit Switch
Used in some homing modes (N.A. yet)
2
0x0004 Home Switch
Used in some homing modes (N.A. yet)
3
0x0008 Zerofly
Flying zero trigger (N.A.)
4
0x0010 Touch Probe 1
Touch Probe input
5
0x0020 Step In
Step signal input (N.A.)
HT7 Ethercat User Guide
32
Содержание EtherCAT HT7
Страница 76: ...www shsitalia it info shsbox shsitalia it 15 ...
Страница 91: ...www shsitalia it info shsbox shsitalia it 2 5 Digital Inputs 2 6 Digital Outputs 14 ...
Страница 92: ...www shsitalia it info shsbox shsitalia it 2 7 Encoder Inputs 15 ...
Страница 95: ...www shsitalia it info shsbox shsitalia it 18 ...
Страница 110: ...www shsitalia it info shsbox shsitalia it 2 5 Digital Inputs 2 6 Digital Outputs 14 ...
Страница 111: ...www shsitalia it info shsbox shsitalia it 2 7 Encoder Inputs 15 ...
Страница 124: ...www shsitalia it info shsbox shsitalia it 28 ...
Страница 125: ...S H S s r l Via F lli Rosselli 29 20027 Rescaldina MI ITALY Tel 39 0331 466918 Fax 39 0331 466147 www shsitalia it ...