Always check that screw for fixing hook clamp or any other fixture is correctly tightened. Attach the unit to to a fix point (truss,…) with the safety hinge cable.

In case of fixing on a solid surface, make sure that fixing bolt is 10mm length (see below).

SOLID SURFACE

Safety Hinge Cable

10mm

SHOWTEX INSTALLATION MANUAL

8

KABUKI 30

2: Fasten hook clamp to channel nut in Kabuki using screw and spring washer (M10x25). Note that US 3/8” bolt can also be used.

1: Insert screw M10 + spring washer in the hook clamp

HOW TO...

FASTEN THE 100 KG HOOK CLAMP

Содержание KABUKI 30

Страница 1: ...INSTALLATION MANUAL KABUKI 30 06 2021 ...

Страница 2: ...is user manual before installing and or operating the automatic reveal system Failure to follow the instructions in this document could result in serious injury As a result of the above warning any ShowTex product must be installed and operated by a qualified technician who has knowledge of its capabilities as well as its limitations Following the guidelines of this manual will reduce the risk of ...

Страница 3: ...environment and people is compromised Note that this is a friction holding system for fabric only Do not hang lighting or any other objects The maximum traction weight mustn t exceed 20kg Overloading can cause damage to the system and endanger the safety of its users and direct environment The operator should always keep an eye on the system during operation and make sure no one walks or places an...

Страница 4: ...ck Info Weight Length 60 cm Length 120 cm 0 08 kg pc 0 11 kg pc 145 95 227 Control unit Article code Colour 8150 0950 0010 Black Info Weight 0 82 kg pc Connection cable 2m Article code Colour 8145 0915 0007 Black Info Weight Length 200 cm 0 45 kg pc 170 110 30 Hook Clamp 100kg Article code Colour 8700 0677 1007 Black Info Weight 100 kg capacity ø 38 51 mm 0 50 kg pc Power Cord True1 Open 2m Articl...

Страница 5: ...SHOWTEX INSTALLATION MANUAL 5 KABUKI 30 ASSEMBLED KABUKI 30 FRONT BACK TOP AND BOTTOM PLAN VIEW Front view Back view Top view Bottom plan view ...

Страница 6: ...SHOWTEX INSTALLATION MANUAL 6 KABUKI 30 SIDE AND EXPLODED VIEW ...

Страница 7: ...100kg Hook Clamp as provided and fix to truss 3 Install all units at appropriate locations 4 Connect all cables 5 Perform safety instruction check up 6 Arm Kabuki 30 7 Insert fabric or 6mm sashline in the gripping zone 8 Repeat operation on other units 9 Trigering the cotrol unit will release the gripping system 10 Check that power trigger does not exceed 30 seconds 11 Go back to step 6 to reload ...

Страница 8: ... of fixing on a solid surface make sure that fixing bolt is 10mm length see below SOLID SURFACE Safety Hinge Cable 10mm SHOWTEX INSTALLATION MANUAL 8 KABUKI 30 2 Fasten hook clamp to channel nut in Kabuki using screw and spring washer M10x25 Note that US 3 8 bolt can also be used 1 Insert screw M10 spring washer in the hook clamp HOW TO FASTEN THE 100 KG HOOK CLAMP ...

Страница 9: ... Schuco main connector 230VAC 0 5A 115VAC 0 75A PowerCON TRUE1 NAC3MX W PowerCON TRUE1 NAC3FX W PowerCON TRUE1 NAC3FX W 3G1 5 3G1 5 3G1 5 3G1 5 Kabuki 30 Remote Unit Next Kabuki 30 SHOWTEX INSTALLATION MANUAL 9 KABUKI 30 CONNECT THE KABUKI AND THE REMOTE CONTROL ...

Страница 10: ...h installation the following steps must be applied to arm the Kabuki After Step 3 the excentric cylinder must be able to move up freely it is now ready to grip fabric or 6mm sashline STEP 1 Push up the excentric cylinder STEP 2 By doing Step 1 reload the lever STEP 3 Release the excentric cylinder ...

Страница 11: ...E 1 Slide the fabric in the gripping system make sure that no extra fabric or end of ribcord goes to far in the unit 2 If the gripping system seems blocked you can t slide material just manually release the system and re arm SASHLINE 6MM RIBCORD 1 2MM Maximum angles of use ...

Страница 12: ...KI MANUALLY 1 The magnet is permanent holding the system won t release if no power trigger is applied manual release is then possibe Pull down the lever shortly but strongly 2 Make sure that re arming is done correctly excentric cylinder must be free to move ...

Страница 13: ...y fabric 4 Check that sashline is 6mm diameter not less not more 5 Check that maximum angles of use are not exceeded 6 Check that fixing bolt for hook clamp or solid surface does not exceed recommended length ITEM W M Y Operate trigger x Listen for unusua noise x Check that a piece of fabric can be released thanks to gravity only x Check state of ruber gripping surface on excentric cylinder x Insp...