CARE & MAINTENANCE
Periodic, regularly scheduled maintenance inspections are necessary for
any mechanical system. A theatrical curtain track system is no different. It
has components that must be inspected, adjusted, maintained and
replaced.
In order to keep your system safe and in good working order, a regular
inspection and maintenance program must be implemented.
Follow the schedule outlined below as a minimum maintenance programme. Once
the operating personnel has had an opportunity to work with the system during the
requirements.
TROUBLE SHOOTING
Please perform the following steps if:
CONTACT & SUPPORT
For more technical assistance, please contact your local ShowTex branch, the address
and contact information can be found on our website:
www.showtex.com
THE FABRIC DOES NOT RELEASE WHEN TRIGGERED
1.
Check that trigger time is sufficient (2 seconds). Pressing to briefly on trigger button is
sometimes not enough.
2.
Check that no extra fabric or end of ribcord is blocked somewhere in casing.
3.
Check that system releases properly without any fabric.
4.
Check that sashline is 6mm diameter (not less, not more).
5.
Check that maximum angles of use are not exceeded.
6.
Check that fixing bolt (for hook clamp or solid surface) does not exceed recommended length.
ITEM
W
M
Y
Operate trigger
x
Listen for unusua noise
x
Check that a piece of fabric can be released thanks to gravity only
x
Check state of ruber gripping surface on excentric cylinder
x
Inspect state of locking nuts and bolts, use same model if necessary
x
Inspect rigging clamps and safety hinge cable
x
Check if the magnet is free of metal particles
x
Check that chaining units operates correctly
x
Inspect state of electrical cables, change if necessary
x
Change ruber gripping sticker
2x
* W = every week
* M = every month
* Y = every year (“2x”= every 2 years)
Within 24hours of using a recently installed system, confirm all these last steps.
The best way to maintain your system is by using it regularly. This will allow the
inspector to regularly check for unusual noise or drag in the system. Above-average
use or operating the system at locations subject to high humidity, dust, extreme
temperature changes, etc. may require shorter intervals than indicated in the
scheduled programme outlined above.