6
Set Up and Operation
Follow the directions below, as they pertain to your preferred operation mode.
Before plugging the unit in, always make sure that the power supply matches the product specification
voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa.
One TriFlood (
Sound Control
)
1.
Fasten the effect light onto firm trussing. Leave at least 0,5 meter on all sides for air circulation.
2.
When the TriFlood is not connected by a DMX-cable, it functions as a stand-alone device.
Multiple TriFloods
1.
Fasten the effect light onto firm trussing
. Leave at least 1 meter on all sides for air circulation.
2.
Use a 3-p XLR cable to connect the Trifloods and other devices.
The pins:
1.
Earth
2.
Signal -
3.
Signal +
3.
Link the units as shown in (figure 5), Connect a DMX signal cable from the first unit's DMX "out" socket to
the second unit's "in" socket. Repeat this process to link the second, third, and fourth units.
4.
Supply electric power: Plug electric mains power cords into each unit's IEC socket, then plug the other
end of the mains power cord into proper electric power supply sockets, starting with the first unit.
Do not supply power before the whole system is set up and connected properly.
Multiple TriFloods Set Up
DMX-Set up
Master/Slave Set up
Fig. 5
Note : Link cables before connecting electric power
Содержание TriFlood
Страница 1: ...TriFlood ORDERCODE 50464 ...
Страница 15: ......