background image

 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due 
to cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your device. Leave 
the device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The device must be installed out of the reach of children. Never leave the unit 
running unattended. 

 

For replacement use lamps and fuses of same type and rating only. 

 

Allow time to cool down, before replacing lamp.  

 

The user is responsible for correct positioning and operating of the TriFlood. The manufacturer will 
not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

During the initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 
 
 

 

 

OPERATING DETERMINATIONS 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light-output and the illuminated surface must be more than 1.3 meter. 

 

The maximum ambient temperature 

t

a

 must never be exceeded. 

 

If this device is operated in any other way, than the one described in this manual, the product may suffer 
damages and the

 

warranty becomes void.  

Any other operation may lead to dangers like short-circuit, burns, electric shock, lamp explosion, crash 
etc. 

 

You endanger your own safety and the safety of others! 

 

Connection with the mains

 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place.

 

 

 International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

FASE 

BLUE 

BLACK 

SILVER 

NUL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 
Make sure that the device is always connected 

properly

 to the earth!  

CAUTION ! EYEDAMAGES !. 

Avoid looking directly into the light source. 

(meant especially for epileptics) !

 

 

Содержание TriFlood

Страница 1: ...TriFlood ORDERCODE 50464 ...

Страница 2: ... Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showtec info You can get some of the best quality best priced products on the market from Showtec So next time turn to Showtec for more great lighting ...

Страница 3: ...ions Description Features and Overview Backside Installation Installing the Lamp Set Up and Operation One TriFlood Multiple TriFloods DMX Protocol Control Modes Stand alone mode Sound Control mode DMX mode Control Panel DMX Channels Maintenance Changing the Lamp Replacing the Fuse Troubleshooting No Light No Response to DMX Product Specifications ...

Страница 4: ... cover is open as discharge lamps may expose and emit a high ultraviolet radiation which may cause burns Do not open the device and do not modify the device Never look directly into the light source Never leave any cables lying around Do not insert objects into air vents Do not connect this device to a dimmerpack Do not switch the device on and off in short intervals as this would reduce the lamp ...

Страница 5: ...by the misuse or incorrect installation of this device This device falls under protection class I Therefore it is essential to connect the yellow green conductor to earth During the initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective Repairs servicing and electric connection must be carried out by a qualified technician...

Страница 6: ... 512 3 DMX modes 2 3 or 4 channels depending on the Control Modi Stand Alone Sound activated Automatic Auto sound master slave mode 16 built in programs Color R G B Lamp 300W 3pcs Lamp 3x R7 S 300W ordercode 82281 NOTE Knowledge of DMX is required to fully utilize this unit Overview Fig 1 1 Mounting bracket 2 Fixation screw ...

Страница 7: ... Always disconnect from electric mains power supply before changing lamps The lamp has to be replaced when it is damaged or deformed due to the heat Do not install lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 1 Loosen the 4 screws on the housing 2 Gently remove th...

Страница 8: ...to firm trussing Leave at least 1 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the Trifloods and other devices The pins 1 Earth 2 Signal 3 Signal 3 Link the units as shown in figure 5 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 4 Supply electric power Plug ele...

Страница 9: ...Mode you can change d 100 Dimmer from 0 100 F 100 Fade from 0 100 S 100 Fade from 0 100 2 Sound Control Mode When the TriFlood is not connected by a DMX cable it functions as a stand alone device By holding down the Mode Button you can switch to Audio the TriFlood will automatically change its color to the beat of the music With the Audio Sensitivity control you can adjust its music sensitivity By...

Страница 10: ...n RGB D C B Mode the device has 3 or 4 channels Mode CH 1 CH 2 CH 3 CH 4 RGB DMX 0 29 Red 0 100 Green 0 100 Blue 0 100 8 Built in programs run automatically DMX 30 94 Dimming 0 100 Fade 0 100 Speed 0 100 8 Built in programs run to sound DMX 95 159 Dimming 0 100 Fade 0 100 Chase automatically DMX 160 184 Dimming 0 100 Fade 0 100 Speed 0 100 Chase to sound DMX 185 209 Dimming 0 100 Fade 0 100 40 Col...

Страница 11: ...d should be 1 A001 the DMX address of the second TriFlood should be 1 4 5 A005 the DMX address of the third TriFlood should be 5 4 9 A009 etc Please be sure that you don t have any overlapping channels in order to control each TriFlood correctly If two or more TriFloods are addressed similarly they will work similarly For address settings please refer to the instructions under Addressing menu Cont...

Страница 12: ...htly connected and must not be corroded 2 There may not be any deformations on housings fixations and installation spots 3 Mechanically moving parts like axles eyes and others may not show any traces of wearing 4 The electric power supply cables must not show any damages or material fatigue The Showtec TriFlood requires almost no maintenance However you should keep the unit clean Otherwise the lig...

Страница 13: ...om the wall all cables etc 3 If all of the above appears to be O K plug the unit in again 4 If you are unable to determine the cause of the problem do not open the device as this may damage the unit and the warranty will become void 5 Return the device to your Showtec dealer No Light This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in ...

Страница 14: ...controller Signal pin OUT pin 1 earth pin 2 pin 3 DMX Channels 4 Signal input 3 pin XLR male Signal output 3 pin XLR female Lamp Allowed lamp models 3x Showtec R7S 300W 1500 hr ordercode 82281 Versions for other lamps may be produced Please check the specification label on your product Design and product specifications are subject to change without prior notice Website www Showtec info Email servi...

Страница 15: ......

Отзывы: