SHOWTEC TriFlood Скачать руководство пользователя страница 4

 

WARNING 

 
 
 
 
 

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY  

BEFORE YOUR INITIAL START-UP! 

 

SAFETY INSTRUCTIONS 

Every person involved with the installation, operation and maintenance of this device has to: 

-

 

be qualified 

-

 

follow the instructions of this manual 

 
 
 
 
 

Before your initial start-up, please make sure that there is no damage caused by transportation. Should 
there be any, consult your dealer and do not use the device. 

 

To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes written in this manual. 

 

Please consider that damages caused by manual modifications to the device are not subject to 
warranty. 

 

This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 

 

IMPORTANT:

 

The manufacturer will not accept liability for any resulting damages caused by the non-
observance of this manual or any unauthorized modification to the device. 

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never run the device without lamp! 

 

Never ignite the lamp if the objective-lens or any housing-cover is open, as discharge lamps may 
expose and emit a high ultraviolet radiation, which may cause burns. 

 

Do not open the device and do not modify the device. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this would reduce the lamp’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot).  

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 
tightly fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always replace the lamp, when it is damaged or deformed due to the heat. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used, before cleaning or when 
replacing lamp! Only handle the power-cord by the plug. Never pull out the plug by tugging the 
power-cord. 

CAUTION! 

Keep this device away from rain and moisture! 

Unplug mains lead before opening the housing! 

CAUTION! Be careful with your operations. 

With a dangerous voltage you can suffer 

a dangerous electric shock when touching the wires!

 

 

Содержание TriFlood

Страница 1: ...TriFlood ORDERCODE 50464 ...

Страница 2: ... Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showtec info You can get some of the best quality best priced products on the market from Showtec So next time turn to Showtec for more great lighting ...

Страница 3: ...ions Description Features and Overview Backside Installation Installing the Lamp Set Up and Operation One TriFlood Multiple TriFloods DMX Protocol Control Modes Stand alone mode Sound Control mode DMX mode Control Panel DMX Channels Maintenance Changing the Lamp Replacing the Fuse Troubleshooting No Light No Response to DMX Product Specifications ...

Страница 4: ... cover is open as discharge lamps may expose and emit a high ultraviolet radiation which may cause burns Do not open the device and do not modify the device Never look directly into the light source Never leave any cables lying around Do not insert objects into air vents Do not connect this device to a dimmerpack Do not switch the device on and off in short intervals as this would reduce the lamp ...

Страница 5: ...by the misuse or incorrect installation of this device This device falls under protection class I Therefore it is essential to connect the yellow green conductor to earth During the initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective Repairs servicing and electric connection must be carried out by a qualified technician...

Страница 6: ... 512 3 DMX modes 2 3 or 4 channels depending on the Control Modi Stand Alone Sound activated Automatic Auto sound master slave mode 16 built in programs Color R G B Lamp 300W 3pcs Lamp 3x R7 S 300W ordercode 82281 NOTE Knowledge of DMX is required to fully utilize this unit Overview Fig 1 1 Mounting bracket 2 Fixation screw ...

Страница 7: ... Always disconnect from electric mains power supply before changing lamps The lamp has to be replaced when it is damaged or deformed due to the heat Do not install lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 1 Loosen the 4 screws on the housing 2 Gently remove th...

Страница 8: ...to firm trussing Leave at least 1 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the Trifloods and other devices The pins 1 Earth 2 Signal 3 Signal 3 Link the units as shown in figure 5 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 4 Supply electric power Plug ele...

Страница 9: ...Mode you can change d 100 Dimmer from 0 100 F 100 Fade from 0 100 S 100 Fade from 0 100 2 Sound Control Mode When the TriFlood is not connected by a DMX cable it functions as a stand alone device By holding down the Mode Button you can switch to Audio the TriFlood will automatically change its color to the beat of the music With the Audio Sensitivity control you can adjust its music sensitivity By...

Страница 10: ...n RGB D C B Mode the device has 3 or 4 channels Mode CH 1 CH 2 CH 3 CH 4 RGB DMX 0 29 Red 0 100 Green 0 100 Blue 0 100 8 Built in programs run automatically DMX 30 94 Dimming 0 100 Fade 0 100 Speed 0 100 8 Built in programs run to sound DMX 95 159 Dimming 0 100 Fade 0 100 Chase automatically DMX 160 184 Dimming 0 100 Fade 0 100 Speed 0 100 Chase to sound DMX 185 209 Dimming 0 100 Fade 0 100 40 Col...

Страница 11: ...d should be 1 A001 the DMX address of the second TriFlood should be 1 4 5 A005 the DMX address of the third TriFlood should be 5 4 9 A009 etc Please be sure that you don t have any overlapping channels in order to control each TriFlood correctly If two or more TriFloods are addressed similarly they will work similarly For address settings please refer to the instructions under Addressing menu Cont...

Страница 12: ...htly connected and must not be corroded 2 There may not be any deformations on housings fixations and installation spots 3 Mechanically moving parts like axles eyes and others may not show any traces of wearing 4 The electric power supply cables must not show any damages or material fatigue The Showtec TriFlood requires almost no maintenance However you should keep the unit clean Otherwise the lig...

Страница 13: ...om the wall all cables etc 3 If all of the above appears to be O K plug the unit in again 4 If you are unable to determine the cause of the problem do not open the device as this may damage the unit and the warranty will become void 5 Return the device to your Showtec dealer No Light This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in ...

Страница 14: ...controller Signal pin OUT pin 1 earth pin 2 pin 3 DMX Channels 4 Signal input 3 pin XLR male Signal output 3 pin XLR female Lamp Allowed lamp models 3x Showtec R7S 300W 1500 hr ordercode 82281 Versions for other lamps may be produced Please check the specification label on your product Design and product specifications are subject to change without prior notice Website www Showtec info Email servi...

Страница 15: ......

Отзывы: