background image

 

  

  

 

 

 

Ordercode: 30730/30731 

Stagebeam MKII 2000W Fresnel 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 

this manual or any unauthorized modification to the device. 

 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 

connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never lift the fixture holding it by the projector-head, as the mechanics may be damaged. Always 

hold the fixture by the transport handles. 

 

Never place any material over the lens. 

 

Never run the device without lamp! 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmer pack. 

 

Do not switch the device on and off in short intervals, as this will reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot). 
Allow the fixture to cool for at least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use the device indoors, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly 

fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep the case closed while operating. 

 

Always replace the lamp, when it is damaged or deformed due to the heat. 

 

Always allow a free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning or when 

replacing lamp! Only handle the power cord holding it by the plug. Never pull out the plug by 
tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 

cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced, so that its functions are not impaired due to 
cracks or deep scratches. 

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 

switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely 

(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The fixture must be installed beyond the reach of children. Never leave the unit 

running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use lamps and fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the Stagebeam. The manufacturer will 

not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

Allow time to cool down, before replacing lamp. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 

conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

Содержание STAGEBEAM MKII 2000W FRESNEL V1

Страница 1: ...Stagebeam MKII 2000W Fresnel V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 30730 30731 MANUAL ENGLISH...

Страница 2: ...tions 4 Rigging 4 Return Procedure 6 Claims 6 Description of the device 7 Overview 7 Installation 8 Installing the Lamp 8 Adjusting the Beam Angle 9 Filter Frame Retaining Clip 9 Set Up and Operation...

Страница 3: ...Your shipment includes Stagebeam MKII 2000W Fresnel with a Schuko power cable 1 m Filter frame User manual Safety Instructions Every person involved with the installation operation and maintenance of...

Страница 4: ...nnect power from the mains when device is not used or before cleaning or when replacing lamp Only handle the power cord holding it by the plug Never pull out the plug by tugging the power cord Make su...

Страница 5: ...t circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safe...

Страница 6: ...s Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE...

Страница 7: ...phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform...

Страница 8: ...t plastic Color Black 30730 Silver 30731 Connections Schuko power cable 1 m Dimensions 425 x 325 x 400 mm LxWxH Weight 6 8 kg Optional accessories 30719 Filterframe Stagebeam 2000 MKII 30736 Barndoor...

Страница 9: ...fered in the future Check your product specification label for information Always disconnect from electric mains power supply before changing lamps The lamp has to be replaced when it is damaged or de...

Страница 10: ...he left or right to increase decrease the beam angle Fig 03 Filter Frame Retaining Clip 01 Push the retaining clip sideways to open 02 Insert the filter frame 03 Release the retaining clip to close 04...

Страница 11: ...t not be corroded 02 There may not be any deformations on housings fixations and installation spots 03 Mechanically moving parts like axles eyes and others may not show any traces of wearing 04 The el...

Страница 12: ...ec dealer 04 If all appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Stagebeam as this may damage the unit and the warranty will beco...

Страница 13: ...lor Black 30730 Silver 30731 Connections Schuko power cable 1 m Allowed lamp models 80805G GY16 GE 80805O GY16 Osram 80805P GY16 Philips 80805S GY16 Sylvania Max ambient temperature ta 25 C Max housin...

Страница 14: ...13 Ordercode 30730 30731 Stagebeam MKII 2000W Fresnel Dimensions...

Страница 15: ...14 Ordercode 30730 30731 Stagebeam MKII 2000W Fresnel...

Страница 16: ...2017 Showtec...

Отзывы: