Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 
tightly fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always replace the lamp, when it is damaged or deformed due to the heat. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used, before cleaning or when 
replacing lamp! Only handle the power-cord by the plug. Never pull out the plug by tugging the 
power-cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

Make sure that no side forces can impact on the truss system. 

 

The cable insert or the female part in the device must never be strained. There must always be 
sufficient cable to the device. Otherwise, the cable may be damaged which may lead to deadly 
electrical shocks. 

 

If the external cable is damaged, it has to be replaced by a qualified technician. 

 

If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due 
to cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your device. Leave 
the device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. City Painter must be installed out of the reach of children. Never leave the unit 
running unattended. 

 

For replacement use lamps and fuses of same type and rating only. 

 

Allow time to cool down, before replacing lamp.  

 

The user is responsible for correct positioning and operating of the City Painter. The manufacturer 
will not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

During the initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 
 
 
 

 

 

 
 
 
 

 
 
 

 
 
 
 

 
 
 

CAUTION ! EYEDAMAGES !. 

Avoid looking directly into the light source. 

(meant especially for epileptics) !

 

 

Содержание LED City Painter 45

Страница 1: ...LED City Painter 45 ORDERCODE 40906...

Страница 2: ...y on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep y...

Страница 3: ...g Description Features and Overview Backside Installation Installing the Lamp Set Up and Operation One City Painter Multiple City Painters Control Panel Control Mode DMX Addressing Multiple City Paint...

Страница 4: ...power cord and all connections with the mains with particular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never run the device witho...

Страница 5: ...is obviously damaged it has to be replaced So that its functions are not impaired due to cracks or deep scratches If device is dropped or struck disconnect mains power supply immediately Have a qualif...

Страница 6: ...ne described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock lamp explosion crash etc You en...

Страница 7: ...g an appropriate safety net or safety cable When rigging derigging or servicing the LED City Painter always make sure that the area below the installation place is blocked and staying in the area is f...

Страница 8: ...Screw provided 2 Turn the bracket 45 to uncover the top fixing screws of the front panel 3 Remove the first two screws with a screwdriver not supplied 4 Turn the head s horizontal positioning bracket...

Страница 9: ...programs with each max 10 scenes DMX control via standard DMX controller Create Programs and scenes to start at a certain time and date 7 DMX control channels required IP 65 Protection degree 24 Red L...

Страница 10: ...DMX signal connector IN 5 DMX signal connector OUT Installation Installing the LED Lights The Showtec LED City Painter 45 uses LED lights LED lights do not have to be replaced Damages caused by non ob...

Страница 11: ...le to connect the City Painters and other devices The pins 1 Earth 2 Signal 3 Signal 3 Link the units as shown in figure 3 Connect a DMX signal cable from the first unit s DMX out socket to the second...

Страница 12: ...e any overlapping channels in order to control each LED City Painter correctly If two or more LED City Painters are addressed similarly they will work similarly For address settings please refer to th...

Страница 13: ...9 197 59 407 30 204 60 414 Colour temperature The CTC channel allows to adjust Palco s colour temperature It acts in a range around the white balance or Full Color according to requirements It s there...

Страница 14: ...Green saturation adjustment 0 100 Channel 5 Blue 0 255 Linear Green saturation adjustment 0 100 Channel 6 CTC Color Correction 0 255 From Cold 2000 K to Warm 2000 k compared to balanced white or not C...

Страница 15: ...13...

Страница 16: ...NTER once you have the intensity you want You now return to the previous menu 7 If you want to exit the entire Colour Balance Menu press and hold down the ENTER button for six seconds 1 Use the UP DOW...

Страница 17: ...ur setting and exit the BOOST menu Note Using BOOST means the overall lifetime of the LEDs goes from 100 000 to 50 000 hours No Function No Function No Function No Function 5 Input Signal The Signal m...

Страница 18: ...tant to set the LED City Painter s internal clock for later use in Stand alone mode 1 Use the UP DOWN buttons to scroll through the display until it shows Time 2 Press and hold down the ENTER button f...

Страница 19: ...ll show Red Press the ENTER button and the fixture will test the RED LEDs Press and hold down the ENTER button for six seconds to return to the previous menu 4 Use the UP DOWN buttons to select RED GR...

Страница 20: ...to choose between ON or OFF 4 Press ENTER to store your setting and exit the Master menu 15 Configuring Slaves When multiple City Painters are connected in stand alone Mode one device has to be the m...

Страница 21: ...UP Button to scroll through the menu until the display shows Dimmer 0 255 Use the UP DOWN buttons to change the value from 0 255 Press the ENTER button to store your setting and return to the previous...

Страница 22: ...ntil it shows Sched1 2 Press the ENTER button and the display will show event 1 36 Use the UP DOWN buttons to change the value from 1 36 Press the ENTER button to store your setting and return to the...

Страница 23: ...tribution Testing Circumstances Installation position horizontal Max Luminous intensity 4569 49 cd Luminous Flux 1640 01 lm Luminous Efficiency 17 50 lm w Source voltage 220 V Current Source 0 777 A P...

Страница 24: ...Replacing a Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse burns out the product will not function whatsoever If this happens follow...

Страница 25: ...Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixtu...

Страница 26: ...g DIP Switches DMX Channels 7 Signal input 3 pin XLR male Signal output 3 pin XLR female IP Protection Grade IP65 Electro mechanical effects DMX control via standard DMX controller Color effect 3 Colo...