background image

 

Ordercode: 43151 

Hydrogen DMX MKII 

Main Menu Options 

 

 

Settings Menu 

 

 

 

Built-in Programs 

 

 

 

DMX address 

 

 

 

Master/Slave Mode 

 
Upon every start-up, the device will reset the software. 

 will appear on the display for a short 

period of time. Subsequently, the device will enter last active mode, before it was switched off. 

 

1.Settings Menu 
Press the MODE button until 

 appears on the display. 

01)  Press the Up or Down button to toggle between the three following menus: 
02) 

 

 

While in this menu, press the SETUP button. The display will shortly flash. When it stops, the color wheel 
has been reset. If the reset process is not completed successfully, 

 

 

will appear on the display.  

 

If this communicate persists, even if the fixture was turned off and on, the fixture is damaged and 

requires an inspection carried out by an authorized technician. 

03) 

 

 

This menu is designed to reset the motor. Press the SETUP button and observe the display. 

 

If 

 appears on the display, the reset process was not completed successfully. 

 

If 

 appears on the display, the reset process was successful. 

04) 

 

 

While in this menu, press the SETUP button and the fixture will restore the factory settings. The motor 

will reset, too. 

 

2.Built-in Programs 

With this menu you can you can set the built-in programs. 
01)

 

Press the MODE button and then the Up / Down buttons, until the display shows 

02)

 

Press the SETUP button to open this menu. 

03)

 

You can use the SETUP button to scroll through the following settings and adjust them, if need be: 

 

 

Program’s run speed, from off to full speed 

 

 

 

Color change speed, from off to a fast-paced change 

 

 

 

LED brightness, from off to very bright 

 

 

 

Strobe settings, 0 = off, 1-99 = from slow to a fast-paced strobe flash 

 

04)

 

Press the MODE button and then the Up / Down buttons, until the display shows 

In this menu, it is not possible to adjust the program’s run speed settings, as well as the color change 

settings. Nevertheless, the LED brightness and strobe settings remain adjustable, just as in case of 

 

 

 

 

  

 

 

14 

   

 

Содержание Hydrogen DMX MKII

Страница 1: ...Hydrogen DMX MKII V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 43151 MANUAL ENGLISH...

Страница 2: ...9 Control Modes 9 One Hydrogen Built in Programs 9 Multiple Hydrogens Master Slave Mode 9 Multiple Hydrogens DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Add...

Страница 3: ...n DMX MKII including a hanging bracket IEC power cable 1 5 m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acceleration...

Страница 4: ...operate the device after having familiarized with its functions Avoid flames and do not put close to flammable liquids or gases Always keep case closed while operating Always allow free air space of a...

Страница 5: ...er way than the one described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock crash etc You...

Страница 6: ...the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER NEUTRAL...

Страница 7: ...umber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this ch...

Страница 8: ...ndard DMX controller 4 DMX channels Fixture Connection XLR Data in out XLR 3 pin 4 digit LED display Housing Black Metal Flame retardant plastic Long LED lifetime Strobe 20Hz Power connector IEC In Ou...

Страница 9: ...DMX is required to fully utilize this unit Installation Remove all packing materials from the Hydrogen DMX MKII Check if all foam and plastic padding is removed Connect all cables Do not supply power...

Страница 10: ...it functions as a stand alone device 05 Please see page 14 15 for more information about the built in programs Multiple Hydrogens Master Slave Mode 01 Fasten the effect light onto firm trussing Leave...

Страница 11: ...ces 05 Link the units as shown in Fig 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 06...

Страница 12: ...digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Hydrogens on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain d...

Страница 13: ...ase make sure that you do not have any overlapping channels in order to control each Hydrogen correctly If two or more Hydrogens are addressed similarly they will work similarly Controlling After havi...

Страница 14: ...Ordercode 43151 Hydrogen DMX MKII Menu Overview 13...

Страница 15: ...button and observe the display If appears on the display the reset process was not completed successfully If appears on the display the reset process was successful 04 While in this menu press the SET...

Страница 16: ...u you can set the Master or Slave 01 Press the MODE button and then the Up and Down buttons until the display shows If the device has not been set to slave it is automatically classified as a master d...

Страница 17: ...power source 02 Insert a screwdriver into the slot in the fuse cover Gently pry up the fuse cover The fuse will come out 03 Remove the used fuse If brown or unclear it is burned out 04 Insert the repl...

Страница 18: ...ted with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and...

Страница 19: ...White Mounting Mounting bracket DMX control Via standard DMX controller On Board Display for easy set up Control DMX 512 Built in Programs Auto Manual color Master Slave Light Source 1 x 20W LED Beam...

Страница 20: ...Ordercode 43151 Hydrogen DMX MKII Dimensions 19...

Страница 21: ...Ordercode 43151 Hydrogen DMX MKII Notes 20...

Страница 22: ...Ordercode 43151 Hydrogen DMX MKII 21...

Страница 23: ...Ordercode 43151 Hydrogen DMX MKII 22...

Страница 24: ...2014 Showtec...

Отзывы: